Description
The Draeger 8103511 is the Benzene Pre-tube detector tube, measuring range Pre-filter tube that lets a PID read benzene selectively (not a measuring tube). Sold by the box of 10, 10 single-use tubes. Accessory tube used ahead of a Draeger detector tube; see the tube's handbook entry for when it is used. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Benzene.
Draeger 8103511 specifications
| Item | Draeger data |
|---|---|
| Part number | 8103511 |
| Gas or substance | Benzene |
| Tube type | Pre-tube |
| Measuring range | Pre-filter tube that lets a PID read benzene selectively (not a measuring tube) |
| Pack | Box of 10 |
| Pump | Accessory tube used ahead of a Draeger detector tube; see the tube's handbook entry for when it is used |
Source: Draeger published product data.
Benzene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | [1910.1028] TWA 1 ppm ST 5 ppm |
| NIOSH REL | Ca TWA 0.1 ppm ST 1 ppm |
| NIOSH IDLH | Ca [500 ppm] |
| CAS number | 71-43-2 |
| Formula | C₆H₆ |
| Conversion | 1 ppm = 3.19 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Benzene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Benzene
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8103691 | Draeger Benzene 0.25/a Detector Tubes, Box of 10 | 0.25 to 2 ppm / 2 to 10 ppm | Box of 10 |
| 8101741 | Draeger Benzene 15/a Detector Tubes, Box of 10 | 15 to 420 ppm | Box of 10 |
| 8101231 | Draeger Benzene 2/a Detector Tubes, Box of 5 | 2 to 60 ppm | Box of 5 |
| 6718801 | Draeger Benzene 5/a Detector Tubes, Box of 10 | 5 to 40 ppm | Box of 10 |
| 6728071 | Draeger Benzene 5/b Detector Tubes, Box of 10 | 5 to 50 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Benzene detector tubes.
Draeger 8103511 questions
What does the Draeger 8103511 measure? Benzene, measuring range Pre-filter tube that lets a PID read benzene selectively (not a measuring tube).
Do Draeger 8103511 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8103511? 10. Each tube is used once.