Description
The Draeger 8101741 is the Benzene 15/a detector tube, measuring range 15 to 420 ppm, 20 to 2 pump strokes, measuring time max. 4 min (handbook, p. 137). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Benzene.
Draeger 8101741 specifications
| Item | Draeger data |
|---|---|
| Part number | 8101741 |
| Gas or substance | Benzene |
| Tube type | 15/a |
| Measuring range | 15 to 420 ppm |
| Number of strokes (n) | 20 to 2 |
| Measuring time | max. 4 min |
| Standard deviation | ± 30 % |
| Color change | white → reddish brown |
| Temperature | 0 to 30 °C |
| Humidity | max. 30 mg H2O/L |
| Reaction principle | a) 2 C6H6 + HCHO → C6H5-CH2-C6H5 + H2O b) C6H5-CH2-C6H5 + H2SO4 → p-quinoid compound |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 137, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 137): Other aromatics (toluene, xylene) are retained in the pre-layer. As a result, this also changes to a reddish brown color. If the concentrations of toluene or xylene are too high, the entire pre-layer through to the indicating layer is discolored, in which case a benzene measurement is not possible. Gasoline hydrocarbons, alcohols, and esters do not affect the reading.
Benzene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | [1910.1028] TWA 1 ppm ST 5 ppm |
| NIOSH REL | Ca TWA 0.1 ppm ST 1 ppm |
| NIOSH IDLH | Ca [500 ppm] |
| CAS number | 71-43-2 |
| Formula | C₆H₆ |
| Conversion | 1 ppm = 3.19 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Benzene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Benzene
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8103511 | Draeger 8103511 PID Pre-Filter Tubes for Benzene, Box of 10 | Pre-filter tube that lets a PID read benzene selectively (not a measuring tube) | Box of 10 |
| 8103691 | Draeger Benzene 0.25/a Detector Tubes, Box of 10 | 0.25 to 2 ppm / 2 to 10 ppm | Box of 10 |
| 8101231 | Draeger Benzene 2/a Detector Tubes, Box of 5 | 2 to 60 ppm | Box of 5 |
| 6718801 | Draeger Benzene 5/a Detector Tubes, Box of 10 | 5 to 40 ppm | Box of 10 |
| 6728071 | Draeger Benzene 5/b Detector Tubes, Box of 10 | 5 to 50 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Benzene detector tubes.
Draeger 8101741 questions
What does the Draeger 8101741 measure? Benzene in air, measuring range 15 to 420 ppm.
How many pump strokes does the 8101741 take? 20 to 2 strokes (n) per the handbook, p. 137. Measuring time max. 4 min.
Which pump does the 8101741 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8101741? white → reddish brown, read against the scale printed on the tube.
Do Draeger 8101741 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8101741? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.