Description
The Draeger 8103691 is the Benzene 0.25/a detector tube, measuring range 0.25 to 2 ppm / 2 to 10 ppm, 5 /1 pump strokes, measuring time approx. 5 min / approx. 1 min (handbook, p. 133). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Benzene.
Draeger 8103691 specifications
| Item | Draeger data |
|---|---|
| Part number | 8103691 |
| Gas or substance | Benzene |
| Tube type | 0.25/a |
| Measuring range | 0.25 to 2 ppm / 2 to 10 ppm |
| Number of strokes (n) | 5 /1 |
| Measuring time | approx. 5 min / approx. 1 min |
| Standard deviation | + 15 % |
| Color change | light gray → dark gray |
| Temperature | 0 to 40 °C |
| Humidity | < 30 mg H2O/L |
| Reaction principle | Benzene Au3+ → dark gray to black reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 133, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 133): Toluene, xylene, and ethylbenzene are retained in the pre-layer up to a concentration of approx. 40 ppm with 5 strokes and 200 ppm with 1 stroke, where they cause a brown discoloration. 800 ppm n-octane with 5 strokes and 4000 ppm with 1 stroke do not discolor the indicating layer.
Benzene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | [1910.1028] TWA 1 ppm ST 5 ppm |
| NIOSH REL | Ca TWA 0.1 ppm ST 1 ppm |
| NIOSH IDLH | Ca [500 ppm] |
| CAS number | 71-43-2 |
| Formula | C₆H₆ |
| Conversion | 1 ppm = 3.19 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Benzene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Benzene
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8103511 | Draeger 8103511 PID Pre-Filter Tubes for Benzene, Box of 10 | Pre-filter tube that lets a PID read benzene selectively (not a measuring tube) | Box of 10 |
| 8101741 | Draeger Benzene 15/a Detector Tubes, Box of 10 | 15 to 420 ppm | Box of 10 |
| 8101231 | Draeger Benzene 2/a Detector Tubes, Box of 5 | 2 to 60 ppm | Box of 5 |
| 6718801 | Draeger Benzene 5/a Detector Tubes, Box of 10 | 5 to 40 ppm | Box of 10 |
| 6728071 | Draeger Benzene 5/b Detector Tubes, Box of 10 | 5 to 50 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Benzene detector tubes.
Draeger 8103691 questions
What does the Draeger 8103691 measure? Benzene in air, measuring range 0.25 to 2 ppm / 2 to 10 ppm.
How many pump strokes does the 8103691 take? 5 /1 strokes (n) per the handbook, p. 133. Measuring time approx. 5 min / approx. 1 min.
Which pump does the 8103691 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8103691? light gray → dark gray, read against the scale printed on the tube.
Do Draeger 8103691 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8103691? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.