The MSA 10046570 is the CBRN cap-1 canister, for Millennium, G1 and Ultra Elite facepieces. The Millennium CBRN canister contains chemical sorbents and a P100 filter to attract, retain, and neutralize contaminants. A NIOSH-approved CBRN APR canister provides protection against a minimum of 139 identified CBRN agents, which are classified into the following 7 families: Organic Vapors, Acid Gases, Base Gases, Hydrides, Nitrogen Oxides, Particulates (composed of chemical, biological, and radiological and nuclear particulate threats), and Formaldehyde. (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021)) NIOSH approval TC-14G-0270. Ships in 1–2 business days; most orders arrive in 3–7 business days.

MSA 10046570 specifications

ItemManufacturer data
MSA part number10046570
CanisterCBRN Cap-1 canister, for Millennium, G1 and Ultra Elite Facepieces
MSA identificationCBRN Cap 1 and CBRN PAPR Cap 1 CANISTER
Protection (CEL)CBRN Cap 1
NIOSH approvalTC-14G-0270 (Millennium, Ultra Elite demand facepiece); TC-14G-0351 (G1 with single port adapter) (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); insert 10046570 REV11 rows: 14G-0270 CBRN Cap 1, 14G-0287 CBRN PAPR Cap 1, 14G-0296, 14G-0298, 14G-0351, 14G-0352
Facepieces MSA namesMillennium, Ultra Elite (demand), G1 with single port adapter (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); "The Advantage 4000 mask is not approved for use with any CBRN or Riot Control canisters." (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC)
MSA packsingle (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC: CBRN Canister, Single)
Shelf life (MSA)PAPR combination cartridges, gas mask canisters, including industrial gas masks, CBRN and Riot control canisters have an expiration date printed on the cartridge label. Generally these are 5 year expiration. (MSA Product Cleaning Guidance 1000-91-MC)

Source: MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; NIOSH Certified Equipment List (November 2026); approval insert 10046570.

Riot control / CBRN canister selection (dsriot)

CanisterMillenniumAdvantage 1000Ultra Elite DemandG1 with single port adapterAdvantage 4000Advantage 3200
10046570 CBRN - SINGLEX TC-14G-0270X TC-14G-0270X TC-14G-0351N/A*
10152979 G1 - RIOT CONTROL SINGLEX TC-14G-0333X TC-14G-0335N/A*
817590 ADVANTAGE RIOT CONTROL 6-PACKX TC-14G-0235N/A*X TC-14G-0235
818264 MILLENNIUM RIOT CONTROL 6-PACKX TC-14G-0254N/A*

* The Advantage 4000 mask is not approved for use with any CBRN or Riot Control canisters.

Source: MSA Riot Control Respiratory Protection for First Responders 1000-102-MC.

NIOSH approval configurations naming the 10046570

The MSA NIOSH approval inserts list 6 approval configurations naming this part:

ApprovalProtection (insert)Approval insertOther cartridges/filters in the row
TC-14G-0270CBRN Cap 1APR CBRN Cap1 Respirator10051287
TC-14G-0287CBRN PAPR Cap 1CBRN Cap1 Canister 1004657010051287
TC-14G-0296CBRN Cap 1CBRN Cap1 Canister 10046570—
TC-14G-0298CBRN PAPR Cap 1CBRN Cap1 Canister 10046570—
TC-14G-0351CBRN Cap 1CBRN Cap1 Canister 10046570—
TC-14G-0352CBRN PAPR Cap 1CBRN Cap1 Canister 10046570—

Source: MSA NIOSH approval inserts APR-CBRN-Cap1-Respirator, CBRN-Cap1-Canister-10046570. Each insert states the respirator is approved only in the listed configurations; the cautions and limitations letters are printed on the insert.

NIOSH approvals naming the 10046570

The NIOSH Certified Equipment List carries 1 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 1 gas mask / CBRN (TC-14G).

ApprovalProduct lineFor protection againstFacepiece
TC-14G-0270Millennium and Ultra Elite CBRN APR with 10046570 canisterCBRN Cap 1Full Facepiece

Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).

MSA gas mask use statements

Gas mask use is restricted to entry into, or work within, atmospheres that are within canister limitations. They are not intended for oxygen-deficient atmospheres (less than 19.5% O2). Gas masks may be used for escape only from atmospheres in which the contaminant concentration does not exceed the gas mask maximum use concentration. Chin-Type Gas Masks have the following maximum use limitations: Routine use: 50 times the Permissible Exposure Level (PEL) - Do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape use: contaminant concentrations up to gas mask maximum use concentrations, providing there is sufficient oxygen to support life. Gas masks are generally suitable for ventilated areas with relatively stable concentration levels. They should never be used within confined spaces, or where oxygen deficiency and/or high gas concentrations may exist.

Never use a gas mask without carefully assessing exposure conditions. Use suitable instruments to determine concentration of oxygen and air contaminants. If exposure concentrations are expected to exceed the specific canister limitations, or are unknown, only a self-contained breathing apparatus or a combination Type C supplied air respirator with auxiliary self-contained air-supply should be used. Always use strictly in accordance with canister labels, gas mask instructions and limitations. DO NOT USE FOR FIREFIGHTING.

Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC.

Assigned protection factor

Respirator type (OSHA Table 1)APF
Air-purifying full facepiece50

Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).

Catalog data

ItemManufacturer data
Filter RatingP100
TypeCanister Filter
ColorBlack
MaterialPlastic; Microglass; Carbon
ResistanceGases; Vapors; Particulates
Filtration GradeHEPA Level Efficiency

Source: Manufacturer published product data as carried in our catalog.

MSA 10046570 CBRN canister is a NIOSH CBRN-approved threaded canister for MSA Millennium and Ultra Elite full facepiece respirators. Approved under TC-14G-0270 with P100 particulate filtration, this CBRN respirator canister is for emergency response and hazardous materials teams.

  • Protection: CBRN (chemical, biological, radiological, nuclear) gas, vapor and particulate
  • Filter rating: P100
  • Connection: threaded
  • Compatible with: MSA Millennium and MSA Ultra Elite facepieces
  • Certification: NIOSH CBRN, TC-14G-0270

Environmental and emergency response contractors stocking Millennium or Ultra Elite facepieces get a matching approved canister. Manufacturer item number: 10046570. Sold individually.

MSA 10046570 questions

What does the MSA 10046570 protect against? The Millennium CBRN canister contains chemical sorbents and a P100 filter to attract, retain, and neutralize contaminants. A NIOSH-approved CBRN APR canister provides protection against a minimum of 139 identified CBRN agents, which are classified into the following 7 families: Organic Vapors, Acid Gases, Base Gases, Hydrides, Nitrogen Oxides, Particulates (composed of chemical, biological, and radiological and nuclear particulate threats), and Formaldehyde. (dsmill) (MSA).

Which facepieces take the 10046570? Millennium, Ultra Elite (demand), G1 with single port adapter (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); "The Advantage 4000 mask is not approved for use with any CBRN or Riot Control canisters." (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC).

Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.

Usually ships in 1–2 business days; delivery in 3–7 business days.

Adding to cart… The item has been added
Specifications
Respirator TypeCartridge
Filter RatingP100
ProtectionCBRN Cap 1
ConnectionThreaded canister (chin-type gas mask)
Compatible WithMillennium, Ultra Elite (demand), G1 with single port adapter (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); "The Advantage 4000 mask is not approved for use with any CBRN or Riot Control canisters." (MSA Riot Control Res
StandardsNIOSH CBRN (TC-14G-0270)
TypeCanister Filter
ColorBlack
MaterialPlastic; Microglass; Carbon
ResistanceGases; Vapors; Particulates
Used WithMSA Millennium®; Ultra Elite® Facepieces
For ModelMillennium®; Ultra Elite®
Chemical CompositionCarbon
Filtration GradeHEPA Level Efficiency
Made in USAYes
MSA Part Number10046570
Shipping & returns

In-stock orders: 1–2 business days to process, then 2–5 business days by ground (3–7 in all); regular rates apply and Contractor Direct orders ship free. Most items can be returned within 30 days in new, resalable condition; respirators, filters and other hygiene items are final sale. Shipping policy · Returns policy

MSA 10046570 CBRN Cap-1 Canister for Millennium, Ultra Elite and G1$120.80

More MSA and other brands in this category

Reviews

No reviews yet. Used this on the job? Tell other crews how it held up.

Write a review ›
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.