Description
The MSA 818264 is the Millennium riot control canisters, box of 6 (818263 Millennium canister). NIOSH approval TC-14G-0254. Ships in 1–2 business days; most orders arrive in 3–7 business days.
MSA 818264 specifications
| Item | Manufacturer data |
|---|---|
| MSA part number | 818264 |
| Canister | Millennium riot control canisters, box of 6 |
| NIOSH classes | P100 |
| Component on the approval insert | 818263 Millennium canister (threaded) (insert 10001974; MSA Advantage 1000 riot control gas mask instruction manual) |
| Protection on the label | P100/CN/CS |
| NIOSH approval | TC-14G-0254 (Millennium w/ 818263 or 817589; CEL) |
| Facepieces MSA names | Millennium Gas Mask (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC) |
| MSA pack | box of 6 |
Source: MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; NIOSH Certified Equipment List (November 2026).
Riot control / CBRN canister selection (dsriot)
| Canister | Millennium | Advantage 1000 | Ultra Elite Demand | G1 with single port adapter | Advantage 4000 | Advantage 3200 |
|---|---|---|---|---|---|---|
| 10046570 CBRN - SINGLE | X TC-14G-0270 | X TC-14G-0270 | X TC-14G-0351 | N/A* | ||
| 10152979 G1 - RIOT CONTROL SINGLE | X TC-14G-0333 | X TC-14G-0335 | N/A* | |||
| 817590 ADVANTAGE RIOT CONTROL 6-PACK | X TC-14G-0235 | N/A* | X TC-14G-0235 | |||
| 818264 MILLENNIUM RIOT CONTROL 6-PACK | X TC-14G-0254 | N/A* |
* The Advantage 4000 mask is not approved for use with any CBRN or Riot Control canisters.
Source: MSA Riot Control Respiratory Protection for First Responders 1000-102-MC.
NIOSH approval configurations naming the 818264
The MSA NIOSH approval inserts list 2 approval configurations naming this part:
| Approval | Protection (insert) | Approval insert | Other cartridges/filters in the row |
|---|---|---|---|
| TC-14G-0235 | P100/CN/CS | CN CS Gas Mask | 817590 |
| TC-14G-0254 | P100/CN/CS | MILLENNIUM CANISTER, P/N 818263 | 10051287 |
Source: MSA NIOSH approval inserts CN-CS-Gas-Mask, Millennium-Canister-818263. Each insert states the respirator is approved only in the listed configurations; the cautions and limitations letters are printed on the insert.
NIOSH approvals naming the 818264
The NIOSH Certified Equipment List carries 1 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 1 gas mask / CBRN (TC-14G).
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-14G-0254 | Millinneum w/ 818263 or 817589 | Chloroacetophenone (CN), Chlorobenzylidene malononitrile (CS), P100 | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).
MSA gas mask use statements
Gas mask use is restricted to entry into, or work within, atmospheres that are within canister limitations. They are not intended for oxygen-deficient atmospheres (less than 19.5% O2). Gas masks may be used for escape only from atmospheres in which the contaminant concentration does not exceed the gas mask maximum use concentration. Chin-Type Gas Masks have the following maximum use limitations: Routine use: 50 times the Permissible Exposure Level (PEL) - Do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape use: contaminant concentrations up to gas mask maximum use concentrations, providing there is sufficient oxygen to support life. Gas masks are generally suitable for ventilated areas with relatively stable concentration levels. They should never be used within confined spaces, or where oxygen deficiency and/or high gas concentrations may exist.
Never use a gas mask without carefully assessing exposure conditions. Use suitable instruments to determine concentration of oxygen and air contaminants. If exposure concentrations are expected to exceed the specific canister limitations, or are unknown, only a self-contained breathing apparatus or a combination Type C supplied air respirator with auxiliary self-contained air-supply should be used. Always use strictly in accordance with canister labels, gas mask instructions and limitations. DO NOT USE FOR FIREFIGHTING.
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Product Type | Riot control canister (CS/CN) |
| Color | Black |
| Packaging | 6/box |
| Type | CS/CN Canister |
Source: Manufacturer published product data as carried in our catalog.
MSA Millennium riot control canisters are 40mm thread gas mask canisters that filter CS and CN agents and particulate. They fit MSA Millennium and Advantage 1000 masks. They are sized for security, corrections and law enforcement teams that keep masks staged.
- Riot control canister for CS and CN agents
- Also filters particulate
- Standard 40mm thread connection
- Fits MSA Millennium and MSA Advantage 1000 gas masks
- Black finish; packaged 6 per box
Security contractors and facility response teams can replace expired canisters across several masks from a single box. Manufacturer item number: 818264. Sold by the box of 6.
Sold by the box
One box holds 6 pieces. The price shown is for the full box; quantity 1 = 1 box (6 pieces).
MSA 818264 questions
What does the MSA 818264 protect against? P100 (MSA).
Which facepieces take the 818264? Millennium Gas Mask (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC).
Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.