Description
The MSA G1 Facepiece is a full facepiece with SCBA mask-mounted regulator. Our part numbers: 10188955 (Medium, 4-pt. polyester head harness), 10188956 (Large, 4-pt. polyester head harness). Sizes Small, Medium, Large. Ships in 1–2 business days; most orders arrive in 3–7 business days. G1: every cartridge, filter, part and NIOSH approval on one page.
MSA G1 Facepiece specifications
| Item | Manufacturer data |
|---|---|
| Facepiece type | Full facepiece |
| Sizes | Small, Medium, Large |
| Our part numbers | 10188955 (Medium, 4-pt. polyester head harness), 10188956 (Large, 4-pt. polyester head harness) |
| Other versions MSA lists | 10188954 (Small, 4-pt. polyester head harness), 10156461 (Small, rubber head harness), 10156462 (Medium, rubber head harness), 10156463 (Large, rubber head harness), 10156458 (Small, 4-pt. Kevlar head harness), 10156459 (Medium, 4-pt. Kevlar head harness), 10156460 (Large, 4-pt. Kevlar head harness), 10161812 (Small, 5-pt. Kevlar head harness), 10161813 (Medium, 5-pt. Kevlar head harness), 10161814 (Large, 5-pt. Kevlar head harness) |
Source: MSA G1 Facepiece Twin Cartridge APR Adapter data sheet 1000-89-MC; MSA G1 Industrial SCBA bulletin 0104-107-MC; MSA Advantage Twin Cartridge Respirators data sheet 1012-42-MC (08.2025); MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC.
MSA canisters we list
| Part number | Canister | Protection | Approval | Facepieces MSA names |
|---|---|---|---|---|
| 10059903 | Phosphine/ammonia/chlorine/P100 canister | Phosphine, Ammonia, Chlorine, P100 | TC-14G-0274 | Chin-type gas mask: G1 (single port APR adapter 10144231-SP required), Advantage 4100 (RD40 adapter 10065330 required), Advantage 3100, Ultravue, Ultra Elite, M |
| 10046570 | CBRN Cap-1 canister, for Millennium, G1 and Ultra Elite Facepieces | CBRN Cap 1 | TC-14G-0270 (Millennium, Ultra Elite demand facepiece); TC-14G-0351 (G1 with single port adapter) (MSA Riot Control Resp | Millennium, Ultra Elite (demand), G1 with single port adapter (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); "The Advantage 4000 ma |
| 817590 | Advantage 1000 Riot Control Agent Canisters, box of 6 | P100 | TC-14G-0235 (Advantage 1000; MSA Riot Control Respiratory Protection for First Responders 1000-102-MC/MSA Advantage 1000 | Advantage 1000 (bayonet canister 817588); Advantage 3200 per MSA Riot Control Respiratory Protection for First Responders 1000-102-MC table (TC-14G-0235) |
| 818264 | Millennium riot control canisters, box of 6 | P100 | TC-14G-0254 (Millennium w/ 818263 or 817589; CEL) | Millennium Gas Mask (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC) |
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021).
Gas mask use is restricted to entry into, or work within, atmospheres that are within canister limitations. They are not intended for oxygen-deficient atmospheres (less than 19.5% O2). Gas masks may be used for escape only from atmospheres in which the contaminant concentration does not exceed the gas mask maximum use concentration. Chin-Type Gas Masks have the following maximum use limitations: Routine use: 50 times the Permissible Exposure Level (PEL) - Do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape use: contaminant concentrations up to gas mask maximum use concentrations, providing there is sufficient oxygen to support life. Gas masks are generally suitable for ventilated areas with relatively stable concentration levels. They should never be used within confined spaces, or where oxygen deficiency and/or high gas concentrations may exist.
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025).
NIOSH approval configurations for the G1 Facepiece
The MSA NIOSH approval insert for this family lists 88 approval configurations; the first 16:
| Approval | Protection | Cartridge, filter or canister in the configuration |
|---|---|---|
| TC-13F-1257 | SC/PD 30 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1258 | SC/PD 45 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1259 | SC/PD 60 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1260 | SC/SA/PD 30 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1261 | SC/SA/PD 45 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1262 | SC/SA/PD 60 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1263 | SC/PD 30 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1264 | SC/PD 45 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1265 | SC/PD 60 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1266 | SC/SA/PD 30 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1267 | SC/SA/PD 45 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1268 | SC/SA/PD 60 MIN 4500 PSIG / EOSTI-29 | — |
| TC-13F-1269 | SC/PD 30 MIN 5500 PSIG / EOSTI-27 | — |
| TC-13F-1270 | SC/PD 45 MIN 5500 PSIG / EOSTI-27 | — |
| TC-13F-1271 | SC/PD 60 MIN 5500 PSIG / EOSTI-27 | — |
| TC-13F-1272 | SC/SA/PD 30 MIN 5500 PSIG / EOSTI-27 | — |
Source: MSA NIOSH approval inserts G1-APR, G1-SCBA-2025_CERT (material 10160485 Rev 11). The insert states the respirator is approved only in the listed configurations.
NIOSH approvals naming the G1 Facepiece
The NIOSH Certified Equipment List carries 198 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 124 SCBA (TC-13F), 7 gas mask / CBRN (TC-14G), 3 supplied-air (TC-19C), 1 powered air-purifying (TC-21C), 13 chemical cartridge (TC-23C), 50 air-purifying particulate (TC-84A). The first 12:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-13F-0785 | Model G1 30 Minute 2216 PSIG Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0785CBRN | Model G1 30 Minute 2216 CBRN Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0786 | Model G1 30 Minute 4500 PSIG Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0786CBRN | Model G1 30 Minute 4500 PSIG CBRN Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0787 | Model G1 45 Minute 4500 PSIG Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0787CBRN | Model G1 45 Minute 4500 PSIG CBRN Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0788 | Model G1 60 Minute 4500 PSIG Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0788CBRN | Model G1 60 Minute 4500 PSIG CBRN Self-Contained Breathing Apparatus | — | Full Facepiece |
| TC-13F-0796 | Model G1, 30 Minute, 2216 PSIG Self Contained Breathing Apparatus or Combination with Type C Supplied Air Respirator | — | Full Facepiece |
| TC-13F-0796CBRN | Model G1 Self Contained Breathing Apparatus, CBRN 30 Minutes, 2216 PSIG | — | Full Facepiece |
| TC-13F-0797 | Model G1, 30 Minute, 4500 PSIG Self Contained Breathing Apparatus or Combination with Type C Supplied Air Respirator | — | Full Facepiece |
| TC-13F-0797CBRN | Model G1 Self Contained Breathing Apparatus, CBRN, 30 Minute, 4500 PSIG | — | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
| Powered air-purifying full facepiece | 1000 |
| Supplied-air respirator, continuous flow, full facepiece | 1000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Material | Rubber |
| Style | Full Face |
Source: Manufacturer published product data as carried in our catalog.
A full facepiece for the MSA G1 industrial SCBA platform, made of rubber with a four-point polyester net head harness. It is the replacement or spare mask for crews running G1 breathing apparatus.
- Full facepiece for MSA G1 industrial SCBA
- Rubber face seal
- 4-point polyester net head harness
- Available in Medium and Large
MSA G1 Facepiece questions
What cartridges fit the MSA G1 Facepiece? SCBA mask-mounted regulator; single-canister APR adapter 10144231-SP; twin-cartridge adapter 10199720
What sizes does the G1 Facepiece come in? Small, Medium, Large: 10188955 (Medium, 4-pt. polyester head harness), 10188956 (Large, 4-pt. polyester head harness).
What is the assigned protection factor of a full facepiece? OSHA Table 1 assigns an APF of 50 to an air-purifying full facepiece.
Guides: half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · cartridge change schedules · P100 vs N95 vs R95 · all respirators by model and hazard.