3M HF-800 Series Secure Click Half Facepiece
The 3M HF-800 Series Secure Click Half Facepiece: HF-801SD (Small), HF-802SD (Medium), HF-803SD (Large); 3M Secure Click connection. Below: every version with a live price, the cartridges and filters 3M lists for it, the parts, the NIOSH approvals from the Certified Equipment List and the OSHA assigned protection factors. Ships in 1–2 business days; most orders arrive in 3–7 business days.
HF-800 Series Secure Click Half Facepiece
| Part number | Item | Version | Price | ||
|---|---|---|---|---|---|
![]() | 7100172045 | 3M Secure Click HF-800 Series Half Facepiece Reusable | HF-801SD - S | $509.06 | |
![]() | 7100172051 | 3M Secure Click HF-800 Series Half Facepiece Reusable | HF-802SD - M | $509.06 | |
![]() | 7100172000 | 3M Secure Click HF-800 Series Half Facepiece Reusable | HF-803SD - L | $53.34 |
Source: 3M Secure Click Half Facepiece Reusable Respirator Series HF-800 technical data (US, (c) 2025); 3M Reusable Respirator Catalog, NIOSH, global English; 3M.com product search by 3M stock number, 2026-11-04 (one card per stock number: name with pack, 3M Stock, Previous 3M Stock, UPC, Alternative ID); NIOSH Certified Equipment List, manufacturer MMM (3M Company), pulled 2026-11-04.
Cartridges and filters 3M lists for the HF-800 Series Secure Click Half Facepiece
| Part number | Item | Version | Price | ||
|---|---|---|---|---|---|
![]() | 7100153170 | 3M D8001 Secure Click Organic Vapor Cartridge D8001: Organic Vapor; 60 ea/Case | $647.76 | ||
![]() | 7100153220 | 3M D8003 Secure Click Organic Vapor/Acid Gas Cartridge D8003: Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide; 60 ea/Case | $705.04 | ||
![]() | 7100153228 | 3M D8006 Secure Click Multi-Gas/Vapor Cartridge D8006: Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde; 60 ea/Case | $23.60 | ||
![]() | 7100153232 | 3M D80921 Secure Click Organic Vapor Cartridge/Filter D80921: Organic Vapor, P100; 60 ea/Case | $42.64 | ||
![]() | 7100153233 | 3M D80923 Respirator Cartridges & Filters, Secure Click Organic Vapor/Acid Gas, P100 D80923: Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100; 60 ea/Case | $43.22 | ||
![]() | 7100153234 | 3M D80926 Secure Click Multi-Gas/Vapor Cartridge D80926: Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100; 60 ea/Case | $47.12 | ||
![]() | 7100213359 | 3M D3091 Secure Click P100 Particulate Filter D3091: P100; 100 EA/Case | $12.11 | ||
![]() | 7100213425 | 3M D3096 Secure Click Particulate Filter, P100 D3096: P100; 100 ea/Case | $842.67 | ||
![]() | 7100213150 | 3M D3097 Secure Click P100 Filter, Nuisance OV Relief D3097: P100 | $830.00 | ||
![]() | 7100213424 | 3M D3076HF Secure Click Particulate Filter, P95/HF D3076HF: Hydrogen Fluoride, P95 | $773.60 | ||
![]() | 7100206894 | 3M D9093 Secure Click Hard Case Particulate Filter, P100 D9093: P100; 60 ea/Case | $475.28 | ||
![]() | 7100206890 | 3M D9093C Secure Click Hard Case Filter, P100 D9093C: Hydrogen Fluoride, P100 | $782.72 | ||
![]() | 7100206896 | 3M D9093CB Secure Click Hard Case Filter, P100 D9093CB: P100 | $1739.33 | ||
![]() | 7100213450 | 3M D7N11 Secure Click Particulate Filter Pad, N95 D7N11: N95; 200 EA/Case | $466.94 | ||
![]() | 7100213434 | 3M D7P71 Secure Click Particulate Filter Pad, P95 D7P71: P95; 200 EA/Case | $579.20 |
Source: Cartridge and Filter Summary for certain 3M Respirators ((c) 2024); 3M Secure Click Half Facepiece Reusable Respirator Series HF-800 technical data (US, (c) 2025); 3M Secure Click Full Facepiece Reusable Respirator FF-800 Series User Instructions.
Parts and accessories
| Part number | Item | Version | Price | ||
|---|---|---|---|---|---|
![]() | 7000001938 | 3M Respirator Cleaning Wipes, Assembly | $65.34 |
Source: 3M Reusable Respirator Catalog, NIOSH, global English; 3M.com product cards.
HF-800 Series Secure Click Half Facepiece series data
| Item | Manufacturer data |
|---|---|
| Facepiece type | half facepiece, reusable, Secure Click |
| Sizes | Small HF-801SD, Medium HF-802SD, Large HF-803SD |
| Stock numbers by size | HF-801SD: 7100172045; HF-802SD: 7100172051; HF-803SD: 7100172000 |
| Materials and weight | Faceseal Silicone Rubber; Fascia Thermoplastic; Inhalation/Exhalation Valve Silicone Rubber; Speaking Diaphragm Thermoplastic, Silicone Rubber, and Polyimide Film; Straps Synthetic Fiber; Buckles Thermoplastic (3M HF-800 technical data). Approximate weight HF-801SD 186 g, HF-802SD 187 g, HF-803SD 194 g (3M HF-800 technical data) |
| Cartridge connection | 3M Secure Click (3M HF-800 technical data; 3M reusable respirator catalog) |
| NIOSH approval statement | HF-800 Series half facepieces are NIOSH approved for use with D8000 Series cartridges, D3000 Series filters, D9000 Series hardcase filters, and D7000 Series filters against a variety of gases, vapors, and particulate hazards. (3M HF-800 technical data) |
| Use limits as the manufacturer states them | HF800 Use: up to 10 times the Permissible Exposure Limit (PEL) with approved 3M cartridges and filters. Not for use in IDLH or oxygen deficient environments. CAT "Assigned Protection Factor" table: Half facepiece respirators and full facepiece respirators that have been qualitatively fit tested, have an APF of 10. Full Facepieces respirators, when quantitatively fit tested, have an APF of 50. (OSHA 29 CFR 1910.134 as quoted by 3M) |
Source: 3M Secure Click Half Facepiece Reusable Respirator Series HF-800 technical data (US, (c) 2025); 3M Reusable Respirator Catalog, NIOSH, global English; 3M.com product search by 3M stock number, 2026-11-04 (one card per stock number: name with pack, 3M Stock, Previous 3M Stock, UPC, Alternative ID); NIOSH Certified Equipment List, manufacturer MMM (3M Company), pulled 2026-11-04.
Features as 3M states them
- CAT comparison: Platform Type 3M Secure Click; Silicone Faceseal; Speaking Diaphragm; Seal Check Button; Compatible with Most Welding Shields; not marked compatible with 3M Supplied Air or PAPR systems
- Spare part HF-800-04 Head Harness Assembly, SD Version, 5/cs (3M HF-800 technical data)
Approval lines recorded from the NIOSH CEL
- TC-23C-3476..3478 "HF-800 Series Half Mask with Chemical Cartridges"
- TC-23C-4116..4119 HF-800 Series with D8002/D8004/D8005/D8009
- TC-84A-8426..8428, 8430 "... Combination Chemical Cartridges and Filters"; 8432..8437 "... Chemical Cartridges and Filters"; 8438, 8439 "HF-800 Series Half Mask with Filters"
- TC-84A-9727 with D80929
Source: NIOSH Certified Equipment List, manufacturer 3M; TC numbers are printed on each product's NIOSH approval label, not in the 3M data sheets fetched.
NIOSH approvals naming the HF-800 Series Secure Click Half Facepiece
The NIOSH Certified Equipment List carries 37 current 3M approvals whose product line names the HF-800 Series Secure Click Half Facepiece: 14 chemical cartridge (TC-23C), 23 air-purifying particulate (TC-84A). The first 15:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-23C-3476 | HF-800 Series Half Mask with Chemical Cartridges | — | Half Mask |
| TC-23C-3477 | HF-800 Series Half Mask with Chemical Cartridges | — | Half Mask |
| TC-23C-3478 | HF-800 Series Half Mask with Chemical Cartridges | — | Half Mask |
| TC-23C-3479 | HF-800 Series Half Mask with China Series Chemical Cartridges | — | Half Mask |
| TC-23C-3480 | HF-800 Series Half Mask with China Series Chemical Cartridges | — | Half Mask |
| TC-23C-3481 | HF-800 Series Half Mask with China Series Chemical Cartridges | — | Half Mask |
| TC-23C-4116 | HF-800 Series, HF-801(S), HF-802(M), HF-803(L), HF-801SD(S), HF-802SD(M), HF-803SD(L), Halfmask, w/Cartridge D8002 | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur | Half Mask |
| TC-23C-4117 | HF-800 Series, HF-801(S), HF-802(M), HF-803(L), HF-801SD(S), HF-802SD(M), HF-803SD(L), Halfmask, w/Cartridge D8004 | Ammonia, Methylamine | Half Mask |
| TC-23C-4118 | HF-800 Series, HF-801(S), HF-802(M), HF-803(L), HF-801SD(S), HF-802SD(M), HF-803SD(L), Halfmask, w/Cartridge D8005 | Formaldehyde, Organic Vapor | Half Mask |
| TC-23C-4119 | HF-800 Series, HF-801(S), HF-802(M), HF-803(L), HF-801SD(S), HF-802SD(M), HF-803SD(L), Halfmask, w/Cartridge D8009 | Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, H | Half Mask |
| TC-23C-4120 | HF-800 Series Half Mask (HF-801 & HF-801SD)(S), (HF-802 & HF-802SD)(M), (HF-803 & HF-803SD)(L), w/D8002CN Cartridge | — | Half Mask |
| TC-23C-4121 | HF-800 Series Half Mask (HF-801 & HF-801SD)(S), (HF-802 & HF-802SD)(M), (HF-803 & HF-803SD)(L), w/D8004CN Cartridge | — | Half Mask |
| TC-23C-4122 | HF-800 Series Half Mask (HF-801 & HF-801SD)(S), (HF-802 & HF-802SD)(M), (HF-803 & HF-803SD)(L), w/D8005CN Cartridge | — | Half Mask |
| TC-23C-4123 | HF-800 Series Half Mask (HF-801 & HF-801SD)(S), (HF-802 & HF-802SD)(M), (HF-803 & HF-803SD)(L), w/D8009CN Cartridge | — | Half Mask |
| TC-84A-8426 | HF-800 Series Half Mask with Combination Chemical Cartridges and Filters | — | Half Mask |
Source: NIOSH Certified Equipment List, manufacturer 3M, read November 4 2026.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying half mask | 10 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Guides: 3M cartridge and filter codes · 3M bayonet vs Secure Click · 6000 vs 6500 vs 7500 · Versaflo TR-300+ vs TR-600 vs TR-800 · what is a PAPR.
3M HF-800 Series Secure Click Half Facepiece questions
Which cartridges fit the HF-800? The Secure Click D8000 Series cartridges, D3000 Series filters, D9000 Series hard case filters and D7000 Series filter pads (3M HF-800 technical data sheet, Approvals).
Does the HF-800 take 3M bayonet cartridges? No. The HF-800 uses the Secure Click connection; the 6000 Series cartridges and 2000 Series filters are bayonet (3M Cartridge and Filter Summary, separate row groups).
What sizes and weights are listed? HF-801SD small 186 g, HF-802SD medium 187 g, HF-803SD large 194 g; SD means speaking diaphragm (technical data sheet).
Can the HF-800 be used with a PAPR or supplied air? The 3M catalog comparison table does not mark the HF-800 as compatible with 3M supplied air or PAPR systems.
What are the use limits? Up to 10 times the PEL with approved 3M cartridges and filters; not for IDLH or oxygen-deficient environments (technical data sheet).
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.