Description
The 3M D8001 is the Secure Click organic vapor cartridge, a gas and vapor cartridge for 3M Secure Click facepieces (HF-800 half facepiece, FF-800 full facepiece). The 3M chart lists it for Organic Vapor. 3M pack: 60 ea/Case. Sold by the each. Ships in 1–2 business days; most orders arrive in 3–7 business days.
3M D8001 specifications
| Item | Manufacturer data |
|---|---|
| 3M part number | D8001 |
| 3M name | Secure Click Organic Vapor Cartridge D8001 |
| Type | Gas and vapor cartridge |
| NIOSH classes (3M chart) | Organic Vapor |
| 3M chart row | OV; OZ ticked (3M Cartridge and Filter Summary (2024)) |
| Fits | 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables) |
| 3M pack | 60 ea/Case |
| End-of-service-life indicator | No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement"). |
Source: 3M Cartridge and Filter Summary (2024); 3M.com product listings (November 2026).
3M stock numbers on this page
| 3M stock number | 3M part number | 3M.com listing name | UPC | Previous stock number |
|---|---|---|---|---|
| 7100153170 | D8001 | 3M Secure Click Organic Vapor Cartridge D8001, 60 ea/Case | 00051131374669 | — |
Source: 3M.com product listings (November 2026); distributor product pages where 3M.com returned no card.
What the 3M chart lists for the D8001
| NIOSH class or note | Status |
|---|---|
| Organic Vapor | Listed by the 3M chart |
| Ozone (not a NIOSH class) | 3M recommendation only; the chart notes the part is not NIOSH approved for ozone |
Source: 3M Cartridge and Filter Summary (2024), cartridge and filter table; 3M 6000 Series half facepiece user instructions, Tables 6 and 7.
3M use notes for the D8001
3M recommended for ozone up to 1ppm for up to 40 hours. Not NIOSH approved for ozone. (3M 6000 Series half facepiece user instructions Table 6 footnote 3; 3M Cartridge and Filter Summary (2024) note 3)
Provided they are stored unopened in the original packaging and away from direct sunlight, humidity and sources of high temperature, cartridges will last five years from manufacture. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7) FAQ)
Source: 3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions; 3M Cartridge and Filter Guide (brochure 70-0714-8870-7).
3M facepieces that take the D8001
| Series | Type | Part numbers |
|---|---|---|
| HF-800 Series Secure Click half facepiece | Half facepiece | HF-801SD, HF-802SD, HF-803SD |
| FF-800 Series Secure Click full facepiece | Full facepiece | FF-801, FF-802, FF-803 |
Source: 3M HF-800 Series technical data (2025); 3M FF-800 Series user instructions
NIOSH approvals
NIOSH does not approve a cartridge or filter on its own; the approval belongs to the facepiece with the cartridge or filter fitted. The CEL product lines for the HF-800 Series, FF-800 Series facepieces name the approved cartridge and filter configurations by type (chemical cartridge, filter, combination cartridge and filter); the 3M approval label packed with the facepiece lists the part numbers.
Source: NIOSH Certified Equipment List (November 2026); 3M user instructions.
Every 3M Secure Click cartridge and filter we list
| Part number | 3M name | NIOSH classes (3M chart) | Label color |
|---|---|---|---|
| D8003 | Secure Click Organic Vapor/Acid Gas Cartridge D8003 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide | — |
| D8006 | Secure Click Multi-Gas/Vapor Cartridge D8006 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde | — |
| D80921 | Secure Click Organic Vapor Cartridge/Filter P100 D80921 | Organic Vapor, P100 | — |
| D80923 | Secure Click Organic Vapor/Acid Gas Cartridge/Filter P100 D80923 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100 | — |
| D80926 | Secure Click Multi-Gas/Vapor Cartridge/Filter P100 D80926 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100 | — |
| D3091 | Secure Click Particulate Filter P100 D3091 | P100 | — |
| D3096 | Secure Click Particulate Filter P100 with Nuisance Level Acid Gas Relief D3096 | P100 | — |
| D3097 | Secure Click Particulate Filter P100 with Nuisance Level Organic Vapor Relief D3097 | P100 | — |
| D3076HF | Secure Click Particulate Cartridge P95/Hydrogen Fluoride with Nuisance Acid Gas Relief D3076HF | Hydrogen Fluoride, P95 | — |
| D9093 | Secure Click Hard Case P100 Particulate Filter D9093 | P100 | — |
| D9093C | Secure Click Hard Case P100 Particulate Filter D9093C, Hydrogen Fluoride and Nuisance Level Organic Vapor/Acid Gas Relief | Hydrogen Fluoride, P100 | — |
| D9093CB | Secure Click Hard Case P100 Particulate Filter D9093CB, with Nuisance Level Acid Gas Relief | P100 | — |
| D7N11 | Secure Click Particulate Filter N95 D7N11 | N95 | — |
| D7P71 | Secure Click Particulate Filter P95 D7P71 | P95 | — |
Source: 3M Cartridge and Filter Summary (2024).
3M™ Secure Click™ D8001 cartridges protect against certain organic vapors, such as those from solvent-based paints, coatings and cleaners. They fit 3M Secure Click HF-800 Series half masks and FF-800 Series full facepieces.
- Secure Click connection for quick, simple attachment
- Dual-flow design for easier breathing
- NIOSH approved when used with 3M Secure Click facepieces
- For industrial and occupational use only
3M D8001 questions
What does the 3M D8001 protect against? The 3M chart lists Organic Vapor. Nuisance-level relief and ozone notes are 3M recommendations, not NIOSH approvals, where the chart marks them.
Which 3M facepieces take the D8001? 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables).
How does 3M pack the D8001? 60 ea/Case.
Does the D8001 have an end-of-service-life indicator? No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").
Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.