Description
The 3M D3097 is the Secure Click P100 particulate filter, a particulate filter for 3M Secure Click facepieces (HF-800 half facepiece, FF-800 full facepiece). The 3M chart lists it for P100. 3M pack: see the 3M.com listing name on the page. Sold by the each. Ships in 1–2 business days; most orders arrive in 3–7 business days.
3M D3097 specifications
| Item | Manufacturer data |
|---|---|
| 3M part number | D3097 |
| 3M name | Secure Click Particulate Filter P100 with Nuisance Level Organic Vapor Relief D3097 |
| Type | Particulate filter |
| NIOSH classes (3M chart) | P100 |
| 3M chart row | P100; Nuis OV; OZ ticked (3M Cartridge and Filter Summary (2024)) |
| Fits | 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables) |
| 3M pack | see the 3M.com listing name on the page |
| End-of-service-life indicator | No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement"). |
Source: 3M Cartridge and Filter Summary (2024); 3M.com product listings (November 2026).
3M stock numbers on this page
| 3M stock number | 3M part number | 3M.com listing name | UPC | Previous stock number |
|---|---|---|---|---|
| 7100213150 | D3097 | 3M Secure Click Particulate Filter P100 with Nuisance Level Organic Vapor Relief D3097, 100 ea/Case | 50051131278160 | — |
Source: 3M.com product listings (November 2026); distributor product pages where 3M.com returned no card.
What the 3M chart lists for the D3097
| NIOSH class or note | Status |
|---|---|
| P100 | Listed by the 3M chart |
| Nuisance level relief (not a NIOSH class) | Nuis OV — 3M suggested for nuisance odor relief from exposure concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower |
| Ozone (not a NIOSH class) | 3M recommendation only; the chart notes the part is not NIOSH approved for ozone |
Source: 3M Cartridge and Filter Summary (2024), cartridge and filter table; 3M 6000 Series half facepiece user instructions, Tables 6 and 7.
3M use notes for the D3097
Nuisance level refers to concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower. Nuisance-level relief is a 3M suggestion, not a NIOSH approval class. (3M Cartridge and Filter Summary (2024) note 2; 3M 6000 Series half facepiece user instructions Table 7 footnote 3)
3M HF-800 Series technical data (2025) footnote 2: "D3097 is 3M recommended for use against up to 1ppm ozone for up to 40 hours. Not NIOSH approved for ozone." 3M FF-800 Series user instructions and 3M Reusable Respirator Catalog (NIOSH) state 8 hours for D3097. Documents disagree; both are 3M recommendations, neither is a NIOSH approval.
For P series filters only when used in environments containing oil aerosols: Dispose of P-Series filters after 40 hours of use or 30 days, whichever is first. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7))
Source: 3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions; 3M Cartridge and Filter Guide (brochure 70-0714-8870-7).
3M facepieces that take the D3097
| Series | Type | Part numbers |
|---|---|---|
| HF-800 Series Secure Click half facepiece | Half facepiece | HF-801SD, HF-802SD, HF-803SD |
| FF-800 Series Secure Click full facepiece | Full facepiece | FF-801, FF-802, FF-803 |
Source: 3M HF-800 Series technical data (2025); 3M FF-800 Series user instructions
NIOSH approvals
NIOSH does not approve a cartridge or filter on its own; the approval belongs to the facepiece with the cartridge or filter fitted. The CEL product lines for the HF-800 Series, FF-800 Series facepieces name the approved cartridge and filter configurations by type (chemical cartridge, filter, combination cartridge and filter); the 3M approval label packed with the facepiece lists the part numbers.
Source: NIOSH Certified Equipment List (November 2026); 3M user instructions.
Every 3M Secure Click cartridge and filter we list
| Part number | 3M name | NIOSH classes (3M chart) | Label color |
|---|---|---|---|
| D8001 | Secure Click Organic Vapor Cartridge D8001 | Organic Vapor | — |
| D8003 | Secure Click Organic Vapor/Acid Gas Cartridge D8003 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide | — |
| D8006 | Secure Click Multi-Gas/Vapor Cartridge D8006 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde | — |
| D80921 | Secure Click Organic Vapor Cartridge/Filter P100 D80921 | Organic Vapor, P100 | — |
| D80923 | Secure Click Organic Vapor/Acid Gas Cartridge/Filter P100 D80923 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100 | — |
| D80926 | Secure Click Multi-Gas/Vapor Cartridge/Filter P100 D80926 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100 | — |
| D3091 | Secure Click Particulate Filter P100 D3091 | P100 | — |
| D3096 | Secure Click Particulate Filter P100 with Nuisance Level Acid Gas Relief D3096 | P100 | — |
| D3076HF | Secure Click Particulate Cartridge P95/Hydrogen Fluoride with Nuisance Acid Gas Relief D3076HF | Hydrogen Fluoride, P95 | — |
| D9093 | Secure Click Hard Case P100 Particulate Filter D9093 | P100 | — |
| D9093C | Secure Click Hard Case P100 Particulate Filter D9093C, Hydrogen Fluoride and Nuisance Level Organic Vapor/Acid Gas Relief | Hydrogen Fluoride, P100 | — |
| D9093CB | Secure Click Hard Case P100 Particulate Filter D9093CB, with Nuisance Level Acid Gas Relief | P100 | — |
| D7N11 | Secure Click Particulate Filter N95 D7N11 | N95 | — |
| D7P71 | Secure Click Particulate Filter P95 D7P71 | P95 | — |
Source: 3M Cartridge and Filter Summary (2024).
Catalog data
| Item | Manufacturer data |
|---|---|
| Style | Particulate Filter |
| Filter Class | P100 |
Source: Manufacturer published product data as carried in our catalog.
A Secure Click P100 particulate filter with relief from nuisance levels of organic vapor odors. It is a common choice for mold remediation and other dusty jobs with light solvent odors.
- NIOSH P100 particulate filter
- Nuisance level organic vapor relief
- Secure Click connection for quick, simple attachment
- Dual-flow design for easier breathing
- For industrial and occupational use only
Sold by the case (100 filters per case).
3M D3097 questions
What does the 3M D3097 protect against? The 3M chart lists P100. Nuisance-level relief and ozone notes are 3M recommendations, not NIOSH approvals, where the chart marks them.
Which 3M facepieces take the D3097? 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables).
How does 3M pack the D3097? see the 3M.com listing name on the page.
Does the D3097 have an end-of-service-life indicator? No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").
Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.