Skip to main content
3M™

3M D9093 Secure Click Hard Case P100 Particulate Filter

Item # 7100206894
$14.99

The 3M D9093 is the Secure Click hard case P100 particulate filter, a particulate filter for 3M Secure Click facepieces (HF-800 half facepiece, FF-800 full facepiece). The 3M chart lists it for P100. 3M pack: 60 ea/Case. Sold by the pack of None. Ships in 1–2 business days; most orders arrive in 3–7 business days.

3M D9093 specifications

ItemManufacturer data
3M part numberD9093
3M nameSecure Click Hard Case P100 Particulate Filter D9093
TypeParticulate filter
NIOSH classes (3M chart)P100
3M chart rowP100 (3M Cartridge and Filter Summary (2024))
Fits3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables)
3M pack60 ea/Case
End-of-service-life indicatorNo end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").

Source: 3M Cartridge and Filter Summary (2024); 3M.com product listings (November 2026).

3M stock numbers on this page

3M stock number3M part number3M.com listing nameUPCPrevious stock number
7100206894D90933M Secure Click Hard Case P100 Particulate Filter D9093, 60 ea/Case50689330191562—

Source: 3M.com product listings (November 2026); distributor product pages where 3M.com returned no card.

What the 3M chart lists for the D9093

NIOSH class or noteStatus
P100Listed by the 3M chart

Source: 3M Cartridge and Filter Summary (2024), cartridge and filter table; 3M 6000 Series half facepiece user instructions, Tables 6 and 7.

3M use notes for the D9093

For P series filters only when used in environments containing oil aerosols: Dispose of P-Series filters after 40 hours of use or 30 days, whichever is first. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7))

Source: 3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions; 3M Cartridge and Filter Guide (brochure 70-0714-8870-7).

3M facepieces that take the D9093

SeriesTypePart numbers
HF-800 Series Secure Click half facepieceHalf facepieceHF-801SD, HF-802SD, HF-803SD
FF-800 Series Secure Click full facepieceFull facepieceFF-801, FF-802, FF-803

Source: 3M HF-800 Series technical data (2025); 3M FF-800 Series user instructions

NIOSH approvals

NIOSH does not approve a cartridge or filter on its own; the approval belongs to the facepiece with the cartridge or filter fitted. The CEL product lines for the HF-800 Series, FF-800 Series facepieces name the approved cartridge and filter configurations by type (chemical cartridge, filter, combination cartridge and filter); the 3M approval label packed with the facepiece lists the part numbers.

Source: NIOSH Certified Equipment List (November 2026); 3M user instructions.

Every 3M Secure Click cartridge and filter we list

Part number3M nameNIOSH classes (3M chart)Label color
D8001Secure Click Organic Vapor Cartridge D8001Organic Vapor—
D8003Secure Click Organic Vapor/Acid Gas Cartridge D8003Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide—
D8006Secure Click Multi-Gas/Vapor Cartridge D8006Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde—
D80921Secure Click Organic Vapor Cartridge/Filter P100 D80921Organic Vapor, P100—
D80923Secure Click Organic Vapor/Acid Gas Cartridge/Filter P100 D80923Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100—
D80926Secure Click Multi-Gas/Vapor Cartridge/Filter P100 D80926Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100—
D3091Secure Click Particulate Filter P100 D3091P100—
D3096Secure Click Particulate Filter P100 with Nuisance Level Acid Gas Relief D3096P100—
D3097Secure Click Particulate Filter P100 with Nuisance Level Organic Vapor Relief D3097P100—
D3076HFSecure Click Particulate Cartridge P95/Hydrogen Fluoride with Nuisance Acid Gas Relief D3076HFHydrogen Fluoride, P95—
D9093CSecure Click Hard Case P100 Particulate Filter D9093C, Hydrogen Fluoride and Nuisance Level Organic Vapor/Acid Gas ReliefHydrogen Fluoride, P100—
D9093CBSecure Click Hard Case P100 Particulate Filter D9093CB, with Nuisance Level Acid Gas ReliefP100—
D7N11Secure Click Particulate Filter N95 D7N11N95—
D7P71Secure Click Particulate Filter P95 D7P71P95—

Source: 3M Cartridge and Filter Summary (2024).

Catalog data

ItemManufacturer data
Filter RatingP100
StyleHard Case
Filter ClassP100

Source: Manufacturer published product data as carried in our catalog.

3M™ Secure Click™ D9093 hard case filters are NIOSH P100 particulate filters for work where particles are the main hazard, such as welding, torch cutting, metal pouring and abatement. They fit 3M Secure Click HF-800 Series half masks and FF-800 Series full facepieces.

  • NIOSH P100, 99.97% filter efficiency
  • Hard case protects the filter media
  • Secure Click connection for quick, simple attachment
  • Suited to welding, brazing, torch cutting, metal pouring and abatement

3M D9093 questions

What does the 3M D9093 protect against? The 3M chart lists P100. Nuisance-level relief and ozone notes are 3M recommendations, not NIOSH approvals, where the chart marks them.

Which 3M facepieces take the D9093? 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables).

How does 3M pack the D9093? 60 ea/Case.

Does the D9093 have an end-of-service-life indicator? No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").

Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.

Usually ships in 1–2 business days; delivery in 3–7 business days.

Adding to cart… The item has been added
Sold by the Pack
Specifications
Respirator TypeFilter
Filter RatingP100
ProtectionP100
StyleParticulate filter
Connection3M Secure Click
Compatible With3M Secure Click HF-800 Series half masks; 3M Secure Click FF-800 Series full facepieces
StandardsNIOSH 42 CFR 84
Filter ClassP100
3M Part NumberD9093
NIOSH RatingP100
Cartridge Connection3M Secure Click
Manufacturer Pack60 ea/Case
Shipping & returns

In-stock orders: 1–2 business days to process, then 2–5 business days by ground (3–7 in all); regular rates apply and Contractor Direct orders ship free. Most items can be returned within 30 days in new, resalable condition; respirators, filters and other hygiene items are final sale. Shipping policy · Returns policy

3M D9093 Secure Click Hard Case P100 Particulate Filter$14.99

More 3M™ and other brands in this category

Reviews

No reviews yet. Used this on the job? Tell other crews how it held up.

Write a review ›
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.