Description
The 3M D80926 is the Secure Click Multi-Gas/Vapor Cartridge/Filter P100, a combination cartridge and filter for 3M Secure Click facepieces (HF-800 half facepiece, FF-800 full facepiece). The 3M chart lists it for Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100. 3M pack: 60 ea/Case. Sold by the pair (2 per pack). Ships in 1–2 business days; most orders arrive in 3–7 business days.
3M D80926 specifications
| Item | Manufacturer data |
|---|---|
| 3M part number | D80926 |
| 3M name | Secure Click Multi-Gas/Vapor Cartridge/Filter P100 D80926 |
| Type | Combination cartridge and filter |
| NIOSH classes (3M chart) | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100 |
| 3M chart row | OV CD CL HC HF HS SD AM/MA FM + P100 (3M Cartridge and Filter Summary (2024)) |
| Fits | 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables) |
| 3M pack | 60 ea/Case |
| End-of-service-life indicator | No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement"). |
Source: 3M Cartridge and Filter Summary (2024); 3M.com product listings (November 2026).
3M stock numbers on this page
| 3M stock number | 3M part number | 3M.com listing name | UPC | Previous stock number |
|---|---|---|---|---|
| 7100153234 | D80926 | 3M Secure Click Multi-Gas/Vapor Cartridge/Filter P100 D80926, 60 ea/Case | 00051141566818 | — |
Source: 3M.com product listings (November 2026); distributor product pages where 3M.com returned no card.
What the 3M chart lists for the D80926
| NIOSH class or note | Status |
|---|---|
| Organic Vapor | Listed by the 3M chart |
| Chlorine Dioxide | Listed by the 3M chart |
| Chlorine | Listed by the 3M chart |
| Hydrogen Chloride | Listed by the 3M chart |
| Hydrogen Fluoride | Listed by the 3M chart |
| Hydrogen Sulfide | Listed by the 3M chart |
| Sulfur Dioxide | Listed by the 3M chart |
| Ammonia | Listed by the 3M chart |
| Methylamine | Listed by the 3M chart |
| Formaldehyde | Listed by the 3M chart |
| P100 | Listed by the 3M chart |
Source: 3M Cartridge and Filter Summary (2024), cartridge and filter table; 3M 6000 Series half facepiece user instructions, Tables 6 and 7.
3M use notes for the D80926
OSHA regulations require gas proof goggles be worn with half facepiece respirators when used against formaldehyde. (3M 6000 Series half facepiece user instructions Table 6 footnote 1)
For P series filters only when used in environments containing oil aerosols: Dispose of P-Series filters after 40 hours of use or 30 days, whichever is first. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7))
Provided they are stored unopened in the original packaging and away from direct sunlight, humidity and sources of high temperature, cartridges will last five years from manufacture. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7) FAQ)
Source: 3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions; 3M Cartridge and Filter Guide (brochure 70-0714-8870-7).
3M facepieces that take the D80926
| Series | Type | Part numbers |
|---|---|---|
| HF-800 Series Secure Click half facepiece | Half facepiece | HF-801SD, HF-802SD, HF-803SD |
| FF-800 Series Secure Click full facepiece | Full facepiece | FF-801, FF-802, FF-803 |
Source: 3M HF-800 Series technical data (2025); 3M FF-800 Series user instructions
NIOSH approvals
NIOSH does not approve a cartridge or filter on its own; the approval belongs to the facepiece with the cartridge or filter fitted. The CEL product lines for the HF-800 Series, FF-800 Series facepieces name the approved cartridge and filter configurations by type (chemical cartridge, filter, combination cartridge and filter); the 3M approval label packed with the facepiece lists the part numbers.
Source: NIOSH Certified Equipment List (November 2026); 3M user instructions.
Every 3M Secure Click cartridge and filter we list
| Part number | 3M name | NIOSH classes (3M chart) | Label color |
|---|---|---|---|
| D8001 | Secure Click Organic Vapor Cartridge D8001 | Organic Vapor | — |
| D8003 | Secure Click Organic Vapor/Acid Gas Cartridge D8003 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide | — |
| D8006 | Secure Click Multi-Gas/Vapor Cartridge D8006 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde | — |
| D80921 | Secure Click Organic Vapor Cartridge/Filter P100 D80921 | Organic Vapor, P100 | — |
| D80923 | Secure Click Organic Vapor/Acid Gas Cartridge/Filter P100 D80923 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100 | — |
| D3091 | Secure Click Particulate Filter P100 D3091 | P100 | — |
| D3096 | Secure Click Particulate Filter P100 with Nuisance Level Acid Gas Relief D3096 | P100 | — |
| D3097 | Secure Click Particulate Filter P100 with Nuisance Level Organic Vapor Relief D3097 | P100 | — |
| D3076HF | Secure Click Particulate Cartridge P95/Hydrogen Fluoride with Nuisance Acid Gas Relief D3076HF | Hydrogen Fluoride, P95 | — |
| D9093 | Secure Click Hard Case P100 Particulate Filter D9093 | P100 | — |
| D9093C | Secure Click Hard Case P100 Particulate Filter D9093C, Hydrogen Fluoride and Nuisance Level Organic Vapor/Acid Gas Relief | Hydrogen Fluoride, P100 | — |
| D9093CB | Secure Click Hard Case P100 Particulate Filter D9093CB, with Nuisance Level Acid Gas Relief | P100 | — |
| D7N11 | Secure Click Particulate Filter N95 D7N11 | N95 | — |
| D7P71 | Secure Click Particulate Filter P95 D7P71 | P95 | — |
Source: 3M Cartridge and Filter Summary (2024).
Catalog data
| Item | Manufacturer data |
|---|---|
| Style | Cartridge / Filter |
| Filter Class | P100 |
Source: Manufacturer published product data as carried in our catalog.
A combination Secure Click cartridge that handles a wide range of gases and vapors plus oil and non-oil particles in one piece. It suits lead paint removal, mold remediation, spray painting and pesticide work.
- Secure Click connection for quick, simple attachment
- Dual-flow design for easier breathing
- NIOSH approved when used with 3M Secure Click facepieces
- For industrial and occupational use only
- Multi-gas/vapor protection plus P100 particulate filter
3M D80926 questions
What does the 3M D80926 protect against? The 3M chart lists Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100. Nuisance-level relief and ozone notes are 3M recommendations, not NIOSH approvals, where the chart marks them.
Which 3M facepieces take the D80926? 3M Secure Click facepieces: HF-800 Series half (HF-801SD/802SD/803SD) and FF-800 Series full (FF-801/802/803) (3M Cartridge and Filter Summary (2024) row group "3M Secure Click Reusable Respirators"; 3M HF-800 Series technical data (2025) Approvals; 3M FF-800 Series user instructions cartridge tables).
How does 3M pack the D80926? 60 ea/Case.
Does the D80926 have an end-of-service-life indicator? No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").
Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.