Skip to main content
Draeger detector tubes · Carbon disulfide

Draeger Carbon Disulfide Detector Tubes

3 Draeger short-term detector tubes for Carbon disulfide, measuring ranges from 0.1 to 10 mg/L up to 5 to 60 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 143–145); prices are live. Ships in 1–2 business days.

Every Draeger tube for Carbon disulfide

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
CH23201Draeger Carbon Disulfide 30/a Detector Tubes, Box of 100.1 to 10 mg/L6approx. 1 minlight blue → brownBox of 10$107.42
8101891Draeger Carbon Disulfide 3/a Detector Tubes, Box of 103 to 95 ppm15 to 1max. 2 minlight blue → yellow-greenBox of 10$141.21
6728351Draeger Carbon Disulfide 5/a Detector Tubes, Box of 105 to 60 ppm11approx. 3 minwhite → brown-greenBox of 10$107.36

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 143–145, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Carbon disulfide exposure limits

LimitValue
OSHA PELTWA 20 ppm C 30 ppm 100 ppm (30-minute maximum peak)
NIOSH RELTWA 1 ppm (3 mg/m³) ST 10 ppm (30 mg/m³) [skin]
NIOSH IDLH500 ppm
CAS number75-15-0
FormulaCS₂
Other namesCarbon bisulfide
Conversion1 ppm = 3.11 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Carbon disulfide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless to faint-yellow liquid with a sweet ether-like odor. [Note: Reagent grades are foul smelling.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Carbon disulfide tube questions

Which Draeger tubes measure Carbon disulfide? CH23201 (0.1 to 10 mg/L), 8101891 (3 to 95 ppm), 6728351 (5 to 60 ppm).

What is the lowest range Draeger tube for Carbon disulfide? CH23201, 0.1 to 10 mg/L, 6 strokes.

What is the OSHA exposure limit for Carbon disulfide? OSHA PEL TWA 20 ppm C 30 ppm 100 ppm (30-minute maximum peak); NIOSH REL TWA 1 ppm (3 mg/m³) ST 10 ppm (30 mg/m³) [skin]; IDLH 500 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Carbon disulfide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Carbon disulfide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.