Skip to main content
Draeger detector tubes · Hydrochloric acid

Draeger Hydrochloric Acid Detector Tubes

3 Draeger short-term detector tubes for Hydrochloric acid, measuring ranges from 0.2 to 3 ppm / 3 to 20 ppm up to 50 to 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 192–194); prices are live. Ships in 1–2 business days.

Every Draeger tube for Hydrochloric acid

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103481Draeger Hydrochloric Acid 0.2/a Detector Tubes, Box of 100.2 to 3 ppm / 3 to 20 ppm10 /2approx. 2 min / 0.4 minblue → yellowBox of 10$137.23
CH29501Draeger Hydrochloric Acid 1/a Detector Tubes, Box of 101 to 10 ppm10approx. 2 minblue → yellowBox of 10$137.14
6728181Draeger Hydrochloric Acid 50/a Detector Tubes, Box of 10500 to 5000 ppm / 50 to 500 ppm1 / 10approx. 30 s / approx. 5 minblue → white-yellowBox of 10$136.86

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 192–194, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Hydrochloric acid (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Hydrochloric Acid MicroTube for X-act 7000, 0.5-25 ppm0.5-25 ppm$121.77

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Hydrochloric acid exposure limits

LimitValue
OSHA PELC 5 ppm (7 mg/m³)
NIOSH RELC 5 ppm (7 mg/m³)
NIOSH IDLH50 ppm
CAS number7647-01-0
FormulaHCl
Other namesAnhydrous hydrogen chloride, Aqueous hydrogen chloride, Hydrochloric acid [Note: Often used in an aqueous solution.]
Conversion1 ppm = 1.49 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen chloride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless to slightly yellow gas with a pungent, irritating odor. [Note: Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Hydrochloric acid tube questions

Which Draeger tubes measure Hydrochloric acid? 8103481 (0.2 to 3 ppm / 3 to 20 ppm), CH29501 (1 to 10 ppm), 6728181 (500 to 5000 ppm / 50 to 500 ppm).

What is the lowest range Draeger tube for Hydrochloric acid? 8103481, 0.2 to 3 ppm / 3 to 20 ppm, 10 /2 strokes.

What is the OSHA exposure limit for Hydrochloric acid? OSHA PEL C 5 ppm (7 mg/m³); NIOSH REL C 5 ppm (7 mg/m³); IDLH 50 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Hydrochloric acid tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Hydrochloric acid tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.