Description
The Draeger 6728181 is the Hydrochloric acid 50/a detector tube, measuring range 500 to 5000 ppm / 50 to 500 ppm, 1 / 10 pump strokes, measuring time approx. 30 s / approx. 5 min (handbook, p. 194). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Hydrochloric acid.
Draeger 6728181 specifications
| Item | Draeger data |
|---|---|
| Part number | 6728181 |
| Gas or substance | Hydrochloric acid |
| Tube type | 50/a |
| Measuring range | 500 to 5000 ppm / 50 to 500 ppm |
| Number of strokes (n) | 1 / 10 |
| Measuring time | approx. 30 s / approx. 5 min |
| Standard deviation | ± 10 to 15 % |
| Color change | blue → white-yellow |
| Temperature | 10 to 50 °C |
| Humidity | max. 15 mg H2O/L |
| Reaction principle | HCl + bromophenol blue → yellowish reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 194, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 194): Hydrogen sulfide and sulfur dioxide have no effect in their OEL ranges. A hydrochloric acid measurement is not possible in the presence of other mineral acids. Chlorine and nitrogen dioxide are also indicated, but with different sensitivities.
Hydrochloric acid exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | C 5 ppm (7 mg/m³) |
| NIOSH REL | C 5 ppm (7 mg/m³) |
| NIOSH IDLH | 50 ppm |
| CAS number | 7647-01-0 |
| Formula | HCl |
| Conversion | 1 ppm = 1.49 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen chloride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Hydrochloric acid
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8103481 | Draeger Hydrochloric Acid 0.2/a Detector Tubes, Box of 10 | 0.2 to 3 ppm / 3 to 20 ppm | Box of 10 |
| CH29501 | Draeger Hydrochloric Acid 1/a Detector Tubes, Box of 10 | 1 to 10 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Hydrochloric acid detector tubes.
Draeger 6728181 questions
What does the Draeger 6728181 measure? Hydrochloric acid in air, measuring range 500 to 5000 ppm / 50 to 500 ppm.
How many pump strokes does the 6728181 take? 1 / 10 strokes (n) per the handbook, p. 194. Measuring time approx. 30 s / approx. 5 min.
Which pump does the 6728181 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 6728181? blue → white-yellow, read against the scale printed on the tube.
Do Draeger 6728181 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 6728181? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.