Description
The Draeger 8103481 is the Hydrochloric acid 0.2/a detector tube, measuring range 0.2 to 3 ppm / 3 to 20 ppm, 10 /2 pump strokes, measuring time approx. 2 min / 0.4 min (handbook, p. 192). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Hydrochloric acid.
Draeger 8103481 specifications
| Item | Draeger data |
|---|---|
| Part number | 8103481 |
| Gas or substance | Hydrochloric acid |
| Tube type | 0.2/a |
| Measuring range | 0.2 to 3 ppm / 3 to 20 ppm |
| Number of strokes (n) | 10 /2 |
| Measuring time | approx. 2 min / 0.4 min |
| Standard deviation | ± 10 to 15 % |
| Color change | blue → yellow |
| Temperature | 5 to 40 °C |
| Humidity | ≤ 15 mg/L |
| Reaction principle | HCl + bromophenol blue → yellow reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 192, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 192): The reading is not affected by 10 ppm H2S and 2 ppm SO2. Other acid gases are also indicated, but with different sensitivities. Chlorine discolors the indicating layer gray. The simultaneous influ- ence of chlorine leads to higher HCl readings.
Hydrochloric acid exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | C 5 ppm (7 mg/m³) |
| NIOSH REL | C 5 ppm (7 mg/m³) |
| NIOSH IDLH | 50 ppm |
| CAS number | 7647-01-0 |
| Formula | HCl |
| Conversion | 1 ppm = 1.49 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen chloride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Hydrochloric acid
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| CH29501 | Draeger Hydrochloric Acid 1/a Detector Tubes, Box of 10 | 1 to 10 ppm | Box of 10 |
| 6728181 | Draeger Hydrochloric Acid 50/a Detector Tubes, Box of 10 | 500 to 5000 ppm / 50 to 500 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Hydrochloric acid detector tubes.
Draeger 8103481 questions
What does the Draeger 8103481 measure? Hydrochloric acid in air, measuring range 0.2 to 3 ppm / 3 to 20 ppm.
How many pump strokes does the 8103481 take? 10 /2 strokes (n) per the handbook, p. 192. Measuring time approx. 2 min / 0.4 min.
Which pump does the 8103481 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8103481? blue → yellow, read against the scale printed on the tube.
Do Draeger 8103481 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8103481? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.