Bayshore Safety & Industrial Supplies Guide
What does EN 407 mean on gloves? The six heat and flame figures (burning behavior, contact heat, convective, radiant, molten metal splashes), the levels 1 to 4 and their temperatures, how it compares with ANSI/ISEA 105, and which gloves carry it
EN 407 is the European standard for gloves that protect against heat and fire. A glove tested to it carries a flame pictogram and up to six digits, one for each test, each scored 1 to 4 (or X where the test was not run): A, burning behavior; B, contact heat; C, convective heat; D, radiant heat; E, small splashes of molten metal; F, large quantities of molten metal. The one most buyers want is B, contact heat, and the levels are temperatures the glove material held for a threshold time over 15 seconds: level 1 is 100 °C (212 °F), level 2 is 250 °C (482 °F), level 3 is 350 °C (662 °F) and level 4 is 500 °C (932 °F), as Armor Guys prints the table in its catalog. The marking says nothing about cut, which is EN 388, and nothing about cold, which is EN 511; and a nitrile-coated HPPE knit with no EN 407 or ANSI heat figure is not a heat glove at all, because, in Armor Guys’ words, "HPPE will start to melt above 158° Fahrenheit". Armor Guys prints the EN 407 marking on its Taeki5 styles, whose knit it rates to 302 °F at 13 and 15 gauge, 482 °F at 10 gauge and up to 662 °F at 7 gauge.
Armor Guys 01-020 Taeki5 Leather Palm Gloves, ANSI A4, EN 407Armor Guys prints the EN 407 marking on the Taeki5 01-020: a sewn leather palm on a 10-gauge Taeki5 knit, rated A4 and EN 388 4X44D, $207.32 a dozenSix tests, six digits. Armor Guys’ catalog lays the standard out as a table, and it is the clearest way to read a marking. Position A, burning behavior, is how long the material keeps burning and glowing after a flame is taken away: level 1 allows an after-flame under 20 seconds with no after-glow requirement, level 2 under 10 seconds of flame and 120 seconds of glow, level 3 under 3 and 25 seconds, level 4 under 2 and 5 seconds. Position B, contact heat, is the temperature the palm material was pressed against for a threshold time over 15 seconds: 212, 482, 662 and 932 °F for levels 1 to 4. Position C, convective heat, is the delay before heat from a flame passes through, over 4, 7, 10 and 18 seconds. Position D, radiant heat, is the same delay against a radiant source, over 7, 20, 50 and 95 seconds. Position E is the number of drops of molten metal the glove took before the skin-simulant behind it registered, over 10, 15, 25 and 35. Position F is the mass of molten metal poured onto the glove without damage to the simulant, over 30, 60, 120 and 200 grams. A glove marked 4 1 3 X 4 X passed the flame test at the top level, held 212 °F for 15 seconds, delayed convective heat for over 10 seconds, was not tested for radiant heat, took over 35 drops of metal and was not tested for a large pour.
What the marking does not say. Nothing about the glove’s cut, abrasion or puncture resistance, which are EN 388 and ANSI/ISEA 105; nothing about cold, which is EN 511; and nothing about chemicals, which is EN ISO 374. A welding glove, a foundry glove and a bakery glove can all carry EN 407 with very different digits, so read the position that matches the hazard. Armor Guys’ three Taeki5 styles print the pictogram; the figure Armor Guys states for the knit is the temperature line in the catalog, not a six-digit code on the product page, and the band shows them that way.
EN 407 position by position
Each figure is the table as Armor Guys prints it in catalog C.009.
The questions, one by one
Answers from the Armor Guys catalog, workbook and product pages named in the byline.
What does the EN 407 standard mean?
It is the European test standard for gloves against thermal risks, heat and fire. A glove that meets it carries the flame pictogram and six performance levels, one per test, so "EN 407" on a glove means the glove was put through some or all of the six tests and scored at least level 1 on the ones it claims. On its own the mark is a statement that the glove was tested for heat; the digits are the result, and a glove with no digits beside the pictogram has to be read from the manufacturer’s data, which for Armor Guys’ Taeki5 is the temperature line in the catalog.
How does EN 407 contact heat compare with the ANSI/ISEA 105 heat levels?
They are different scales on the same idea. ANSI/ISEA 105 rates conductive (contact) heat in five levels, as the manufacturers in the comparison band print them: level 1 at 80 °C (176 °F), level 2 at 140 °C (284 °F), level 3 at 200 °C (392 °F), level 4 at 260 °C (500 °F) and level 5 at 320 °C (608 °F). EN 407 contact heat has four levels at 100, 250, 350 and 500 °C. So an EN 407 contact level 2 (482 °F) sits a little below an ANSI level 4 (500 °F), and an EN 407 level 3 (662 °F) is above the top of the ANSI scale. Armor Guys’ workbook notes that ANSI/ISEA 105-2024 updated its conductive heat classifications; the levels the manufacturers in the band print are the ones they tested to.
Will a nitrile-coated cut-resistant glove take heat?
Not as a heat glove. Armor Guys’ catalog states that HPPE, the fiber in most cut-resistant knits, "will start to melt above 158° Fahrenheit", and it prints no heat figure on its micro-foam nitrile Kyorene, Basetek or Extraflex styles. The band lists three of them that way, "no heat rating stated", because people ask. For warm parts off a machine, the Taeki5 knit is the Armor Guys answer: 302 °F at 13 and 15 gauge, 482 °F at 10 gauge, up to 662 °F at 7 gauge, by the catalog, with the EN 407 pictogram printed on the 01-006, 01-020 and 01-017.
Which gloves for hot parts, and which for firewood or a log burner?
For parts that are warm to hot and also sharp, a heat-marked cut-resistant knit like the Taeki5 leather-palm styles (A4, EN 388 4X44D, leather over a 10-gauge Taeki5 knit). For dry radiant heat and the odd hot surface, a leather glove with a stated ANSI contact heat level 3 or 4, which the comparison band shows. Firewood and a log burner are the second case; what matters there is the contact heat position (B) and a cuff long enough to cover the wrist, and no synthetic knit with no heat figure.
What is the difference between contact heat and convective heat?
Contact heat (B) is touching a hot object: the test presses the palm material against a hot plate and times how long the inside stays within 10 °C of where it started. Convective heat (C) is the heat of a flame reaching the hand through moving air, timed as a transfer delay. A glove can score well on one and X on the other; for handling parts off an oven or a press, B is the one to read.
Does an EN 407 glove protect against molten metal?
Only if positions E and F carry a level, and the two tests are different: E is small drops (a welder’s spatter), F is a large quantity (a pour). A glove marked X in both positions was not tested for molten metal, whatever its contact heat level says. None of the Armor Guys styles we carry claims E or F; the welding guide linked below covers the leather gloves that do.
Does OSHA require EN 407 gloves?
No. OSHA’s hand protection rule, 29 CFR 1910.138, lists "thermal burns" and "harmful temperature extremes" among the hazards an employer must select gloves for, and leaves the performance figure to the employer’s hazard assessment; EN 407 and the ANSI/ISEA 105 heat levels are the figures manufacturers print so that the selection can be shown to match the hazard. Neither standard is written into the rule.
Can a heat-rated glove be cut rated too?
Yes, and the Taeki5 styles are: Armor Guys prints ANSI/ISEA 105 A4 and EN 388 4X44D on the 01-006 and 01-020 and A2 and EN 388 4X4XB on the 01-017 liner beside the EN 407 pictogram. The two standards test different things and both markings go on the glove.
In plain words
- EN 407 is the European heat-and-flame standard: a flame pictogram and up to six digits, each 1 to 4, for flame, contact heat, convective heat, radiant heat, metal splashes and metal pours.
- Contact heat, the second digit, is the one for hot parts: level 1 is 212 °F, level 2 482 °F, level 3 662 °F, level 4 932 °F, held for 15 seconds.
- An X means that test was not run. The marking says nothing about cut (EN 388), cold (EN 511) or chemicals (EN ISO 374).
- A nitrile-coated HPPE knit with no heat figure is not a heat glove; Armor Guys prints that HPPE starts to melt above 158 °F.
- Armor Guys prints the EN 407 marking on its Taeki5 styles and rates the Taeki5 knit at 302 °F (13 and 15 gauge), 482 °F (10 gauge) and up to 662 °F (7 gauge).
Questions people ask
What does EN 407 mean on gloves?
The European heat and flame standard: a flame pictogram with up to six digits (1 to 4 each) for burning behavior, contact heat, convective heat, radiant heat, small splashes and large quantities of molten metal.
What temperature is EN 407 contact heat level 2?
250 °C (482 °F), held for a threshold time over 15 seconds, per the table Armor Guys prints; level 1 is 100 °C, level 3 350 °C, level 4 500 °C.
What does X mean in an EN 407 code?
That position was not tested or does not apply, the same convention as EN 388.
Is EN 407 the same as the ANSI heat rating?
No; ANSI/ISEA 105 rates contact heat in five levels from 80 °C to 320 °C, EN 407 in four from 100 °C to 500 °C, and the two are not interchangeable.
Are cut-resistant gloves heat resistant?
Only when a heat figure is printed; Armor Guys states HPPE starts to melt above 158 °F and prints the EN 407 marking only on its Taeki5 styles.
Which Armor Guys gloves carry EN 407?
The Taeki5 01-006 and 01-020 leather-palm gloves (A4) and the 01-017 liner (A2), as the product pages print.
Does EN 407 cover molten metal?
Positions E (small splashes) and F (large quantities) do, when they carry a level; an X there means no molten-metal test.
Does OSHA require an EN 407 glove?
No; 1910.138 requires gloves selected for thermal burns and temperature extremes and leaves the figure to the employer’s assessment.
Related guides
Heat-resistant glovesThe ANSI/ISEA 105 heat and flame levelsWill nitrile gloves melt in heat?What a nitrile coating and an HPPE shell are rated forEN 388 explainedThe four numbers and the letters on a gloveThe ASTM, ANSI/ISEA and EN standards for glovesEvery standard printed on a gloveWhich gloves are used for welding?Leather by process, cuff and liningCold-weather work glovesWhat the EN 511 ratings meanHow are cut-resistant gloves rated and tested?The TDM-100 test, the gram scores and the 2024 badgeOSHA 1910.138 Hand ProtectionThe rule pageThe ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.