Description
The RKI Instruments ESR-B134-NH3 is a replacement electrochemical ammonia (NH3) sensor for the GX-3R Pro and SC-04. On the GX-3R Pro the NH3 channel reads 0-400.0 ppm (0.5 ppm), as RKI states. Part of GX-3R Pro sensors and parts. Ships in 1–2 business days; most orders arrive in 3–7 business days.
RKI Instruments ESR-B134-NH3 specifications
| Item | RKI Instruments data |
|---|---|
| Part number | ESR-B134-NH3 |
| Type | Ammonia Sensor |
| RKI parts-list description | Sensor, Ammonia (NH3) 0-400 ppm for GX-3R Pro / SC-04 |
| RKI sensor type | ESR-B134 |
| Gas detected | Ammonia (NH3) |
| Measuring range on the GX-3R Pro | 0-400.0 ppm (0.5 ppm) |
| RKI preset alarms on the GX-3R Pro | A1 25.0 ppm, A2 35.0 ppm, A3 300.0 ppm (the TWA and STEL figures on the RKI page are printed out of order and are not repeated here) |
| Measuring range on the SC-04 | 0-400.0 ppm (0.5 ppm) |
| RKI preset alarms on the SC-04 | A1 25.0 ppm, A2 35.0 ppm, A3 300.0 ppm, TWA 25.0 ppm, STEL 35.0 ppm |
| Fits | GX-3R Pro, SC-04 |
Source: RKI Instruments GX-3R Pro product page https://www.rkiinstruments.com/product/gx-3r-pro-gas-detector/ (ranges and alarm presets); RKI Instruments SC-04 product page https://www.rkiinstruments.com/product/04-series-single-gas-detectors/ (ranges and alarm presets); RKI Instruments 2026 parts list (description).
Instruments the ESR-B134-NH3 fits
| Instrument | What RKI states | On our site | Price |
|---|---|---|---|
| GX-3R Pro | Named in the RKI Instruments 2026 parts list. | Every GX-3R Pro configuration we stock (334) | see current prices |
| SC-04 | Named in the RKI Instruments 2026 parts list. | RKI Instruments 73-0077 Single Gas Monitors, SC-04 Single-Gas Monitor NH3 | $442.00 |
Source: RKI Instruments 2026 parts list. A model we stock links to every configuration of it; the price shown is the lowest configuration.
Ammonia exposure limits
| Gas | CAS | OSHA PEL | NIOSH REL | NIOSH IDLH |
|---|---|---|---|---|
| Ammonia (NH3) | 7664-41-7 | TWA 50 ppm (35 mg/m³) | TWA 25 ppm (18 mg/m³) ST 35 ppm (27 mg/m³) | 300 ppm |
Source: NIOSH Pocket Guide to Chemical Hazards: Ammonia (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. The limits are the published values, not a recommendation; the alarm presets a monitor ships with are RKI's and are in the specification table above.
RKI Instruments documents
- RKI Instruments GX-3R Pro datasheet (PDF)
- RKI Instruments GX-3R Pro manual CSA/ATEX Approval Version (PDF)
- RKI Instruments GX-3R Pro quick reference card (PDF)
- RKI Instruments 04-Series datasheet (PDF)
- RKI Instruments SC-04 operator's manual (PDF)
- RKI Instruments 04 Series Quick User Guide (PDF)
Source: RKI Instruments GX-3R Pro product page https://www.rkiinstruments.com/product/gx-3r-pro-gas-detector/; RKI Instruments SC-04 product page https://www.rkiinstruments.com/product/04-series-single-gas-detectors/ (downloads list).
RKI Instruments ESR-B134-NH3 questions
What is the RKI ESR-B134-NH3 sensor? A replacement electrochemical ammonia (NH3) sensor for the GX-3R Pro and SC-04. The specification table above gives the range and RKI's preset alarms on each instrument it fits.
What instruments does the ESR-B134-NH3 fit? The GX-3R Pro and SC-04 we stock. The fits table above says which RKI document names each one.
What range does the ESR-B134-NH3 read? 0-400.0 ppm (0.5 ppm) on the GX-3R Pro, as RKI states; RKI's preset alarms on the GX-3R Pro are A1 25.0 ppm, A2 35.0 ppm, A3 300.0 ppm (the TWA and STEL figures on the RKI page are printed out of order and are not repeated here).
Guides: when to replace sensors · bump test vs calibration · how to read a gas monitor alarm · ammonia exposure limits · every RKI replacement sensor by gas · the four sensor types and how to read a 4-gas meter.
Manufacturer item number: ESR-B134-NH3.
Replacement ammonia (NH3) electrochemical sensor, RKI type ESR-B134, for the GX-3R Pro and 04 Series gas monitors.