RKI Instruments 04 Series Single-Gas Monitors
Every 04 Series configuration we stock, with its price and add to cart: 9 part numbers; 04 Series is RKI's pocket-size single gas detectors (2.8 oz, IP-67) that run on two AAA alkaline cells for months at a time: HS-04 (H2S), CO-04 and CO-04C (CO, the C with hydrogen elimination), OX-04 (O2), the CX-04 CO and O2 dual sensor, and the SC-04 for one toxic gas (HCN, NH3, NO2, PH3 or SO2). Figures below are as published by RKI Instruments. Ships in 1–2 business days; most orders arrive in 3–7 business days.
Related series: 04 Series sensors and parts.
04 Series monitors by part number
| Part number | Model | Gases | Run time | Battery | Price | ||
|---|---|---|---|---|---|---|---|
![]() | 73-0063 | HS-04 | H2S | 9,000 hours | Alkaline | $174.25 | |
![]() | 73-0065 | CO-04 | CO | 9,000 hours | Alkaline | $174.25 | |
![]() | 73-0067 | CO-04C | CO | 6,200 hours | Alkaline | $442.00 | |
![]() | 73-0081 | SC-04 | SO2 | 6,200 hours (RKI page summary for the HCN, NO2, PH3 and SO2 versions) | Alkaline | $442.00 | |
![]() | 73-0071 | SC-04 | HCN | 6,200 hours (RKI page summary for the HCN, NO2, PH3 and SO2 versions) | Alkaline | $442.00 | |
![]() | 73-0077 | SC-04 | NH3 | 3,000 hours | Alkaline | $442.00 | |
![]() | 73-0073 | SC-04 | NO2 | 6,200 hours (RKI page summary for the HCN, NO2, PH3 and SO2 versions) | Alkaline | $442.00 | |
![]() | 73-0079 | SC-04 | PH3 | 6,200 hours (RKI page summary for the HCN, NO2, PH3 and SO2 versions) | Alkaline | $442.00 | |
![]() | 73-0069 | CX-04 | O2/CO | 4,600 hours | Alkaline | $442.00 |
Source: RKI Instruments product data file, Sept 2026 (configuration per part number); prices from the store.
04 Series specifications
| Item | RKI Instruments data |
|---|---|
| Sample method | Diffusion |
| Power source | Two AAA alkaline cells; continuous operation HS-04 9,000 hours; CO-04 9,000 hours; CO-04C 6,200 hours; OX-04 3,000 hours; CX-04 4,600 hours; SC-04 6,200 hours (SC-04 NH3 3,000 hours) |
| Display | Digital LCD: gas name and concentration, auto backlight during alarm, operation and battery icons |
| Alarms | Gas alarm: 1st, 2nd and 3rd (user adjustable), OVER, STEL and TWA. Trouble alarm: sensor connection, low battery, circuit failure, calibration range error |
| Alarm display | Flashing LEDs, intermittent buzzer, flashing gas value and vibration |
| Response time | T90 in 30 seconds |
| Operating temperature and humidity | -20 to +50 °C (-4 to +122 °F), 0 to 90% RH non-condensing |
| Case | IP-67 |
| Dimensions | 2.1 in W x 2.64 in H x 0.94 in D (54 x 67 x 24 mm) |
| Weight | 2.8 oz (80 g) |
| Datalogging | 10-second intervals = 10 hours; 5-minute = 300 hours; 10-minute = 600 hours. Records alarms, alarm trends, gas readings, calibration and bump test history, settings |
| Standard accessories | Rubber boot, datalogging software, alligator clip, alkaline batteries |
| Optional accessories | Calibration cap, wrist strap, calibration kit, belt clip, datalogging download cable |
| Approvals | ATEX/IECEx approved; QPS classified C/US as intrinsically safe, Class I, Division 1, Groups A, B, C, D |
| Warranty | 3 year warranty (1 year for ammonia and chlorine sensors) |
Source: RKI Instruments product page https://www.rkiinstruments.com/product/04-series-single-gas-detectors/, fetched Nov 8 2026 (common specifications).
04 Series detectable gases
| Gas | Sensor | Measuring range (increment) | Accuracy | Preset alarms |
|---|---|---|---|---|
| H2S | Electrochemical | 0 - 200.0 ppm (0.1 ppm) | ± 5% of reading or ± 2 ppm H2S | A1 5 ppm; A2 30.0 ppm; A3 100.0 ppm; TWA 1.0 ppm; STEL 5.0 ppm |
| CO | Electrochemical | 0 - 2,000 ppm (1 ppm) | ± 5% of reading or ± 5 ppm CO | A1 25 ppm; A2 50 ppm; A3 1,200 ppm; TWA 25 ppm; STEL 200 ppm |
| CO (H2-compensated sensor) | Electrochemical, H2 elimination | 0 - 2,000 ppm (1 ppm) | ± 5% of reading or ± 2 ppm CO | A1 25 ppm; A2 50 ppm; A3 1,200 ppm; TWA 25 ppm; STEL 200 ppm |
| O2 | Electrochemical | 0 - 40% vol (0.1%) | ± 0.5% O2 | A1 19.5% vol; A2 18.0% vol; A3 23.5% vol |
| NH3 | Electrochemical | 0 - 400.0 ppm (0.5 ppm) | ± 10% of reading or ± 5% of full scale | A1 25.0 ppm; A2 35.0 ppm; A3 300.0 ppm; TWA 25.0 ppm; STEL 35.0 ppm |
| Cl2 | Electrochemical | 0 - 20.00 ppm (0.05 ppm) | ± 10% of reading or ± 5% of full scale | A1 1.00 ppm; A2 2.00 ppm; A3 10.00 ppm; TWA 0.50 ppm; STEL 1.00 ppm |
| HCN | Electrochemical | 0 - 30.0 ppm (0.1 ppm) | ± 10% of reading or ± 5% of full scale | A1 5.0 ppm; A2 10.0 ppm; A3 30.0 ppm; TWA 4.7 ppm; STEL 10.0 ppm |
| NO2 | Electrochemical | 0 - 20.00 ppm (0.05 ppm) | ± 10% of reading or ± 5% of full scale | A1 2.0 ppm; A2 4.0 ppm; A3 20.00 ppm; TWA 0.50 ppm; STEL 1.00 ppm |
| PH3 | Electrochemical | 0 - 20.00 ppm (0.01 ppm) | ± 10% of reading or ± 5% of full scale | A1 0.30 ppm; A2 0.60 ppm; A3 1.00 ppm; TWA 0.30 ppm; STEL 1.00 ppm |
| SO2 | Electrochemical | 0 - 100.00 ppm (0.05 ppm) | ± 10% of reading or ± 5% of full scale | A1 2.00 ppm; A2 5.00 ppm; A3 100.0 ppm; TWA 2.00 ppm; STEL 5.00 ppm |
Source: RKI Instruments product page https://www.rkiinstruments.com/product/04-series-single-gas-detectors/, fetched Nov 8 2026 (detectable gases table). Preset alarms are RKI factory settings, user adjustable.
Exposure limits for the gases the 04 Series detects
| Gas | CAS | OSHA PEL | NIOSH REL | NIOSH IDLH |
|---|---|---|---|---|
| Hydrogen sulfide (H2S) | 7783-06-4 | C 20 ppm 50 ppm [10-minute maximum peak] | C 10 ppm (15 mg/m³) [10-minute] | 100 ppm |
| Carbon monoxide (CO) | 630-08-0 | TWA 50 ppm (55 mg/m³) | TWA 35 ppm (40 mg/m³) C 200 ppm (229 mg/m³) | 1200 ppm |
| Sulfur dioxide (SO2) | 7446-09-5 | TWA 5 ppm (13 mg/m³) | TWA 2 ppm (5 mg/m³) ST 5 ppm (13 mg/m³) | 100 ppm |
| Hydrogen cyanide (HCN) | 74-90-8 | TWA 10 ppm (11 mg/m³) [skin] | ST 4.7 ppm (5 mg/m³) [skin] | 50 ppm |
| Ammonia (NH3) | 7664-41-7 | TWA 50 ppm (35 mg/m³) | TWA 25 ppm (18 mg/m³) ST 35 ppm (27 mg/m³) | 300 ppm |
| Nitrogen dioxide (NO2) | 10102-44-0 | C 5 ppm (9 mg/m³) | ST 1 ppm (1.8 mg/m³) | 13 ppm |
| Phosphine (PH3) | 7803-51-2 | TWA 0.3 ppm (0.4 mg/m³) | TWA 0.3 ppm (0.4 mg/m³) ST 1 ppm (1 mg/m³) | 50 ppm |
29 CFR 1910.146(b) defines a hazardous atmosphere to include a flammable gas, vapor or mist in excess of 10 percent of its lower flammable limit (LFL), an atmospheric oxygen concentration below 19.5 percent or above 23.5 percent, and any atmospheric concentration of a substance that could result in employee exposure in excess of its dose or permissible exposure limit.
Source: NIOSH Pocket Guide to Chemical Hazards; 29 CFR 1910.146(b). Published limits, not a recommendation for any task.
04 Series documents
- 04-Series Product Datasheet (PDF) - datasheet
- 04 Series Quick User Guide (PDF) - quick reference card
- 04 Series User Setup Program Operator's Manual (PDF) - setup program manual
- 04 Series Data Logger Management Program Operator's Manual (PDF) - datalogging manual
- SC-04 Operator's Manual (PDF) - operator's manual
- CO-04 Operator's Manual (PDF) - operator's manual
- CX-04 Operator's Manual (PDF) - operator's manual
- HS-04 Operator's Manual (PDF) - operator's manual
- CO-04C Operator's Manual (PDF) - operator's manual
- OX-04 Operator's Manual (PDF) - operator's manual
Source: RKI Instruments 04 Series downloads, RKI Instruments product page https://www.rkiinstruments.com/product/04-series-single-gas-detectors/, fetched Nov 8 2026.
04 Series features
- Continuously operate for over one year (H2S & CO)
- Toxic gases include: NH3, Cl2, HCN, NO2, PH3 & SO2
- CO with H2 elimination
- CO & O2 Dual Sensor
- Field serviceable
- Pocket size 2.1"(W) x 2.6"(H) x 0.9"(D), 2.8 ounces
- Impact, dust, and water resistant (IP-67)
- Replaceable rubber boot
- Alligator clip with 360° rotation
- Audible / visual / vibration alarms
- Automatic backlight
- Intrinsically safe, ATEX and C / US approvals
- 3 Year warranty*
Source: RKI Instruments feature list, RKI Instruments product page https://www.rkiinstruments.com/product/04-series-single-gas-detectors/, fetched Nov 8 2026.
Guides: what a 4-gas monitor measures · bump test vs calibration · how to read a gas monitor alarm · confined space gas testing order · what Class I Div 1 means · sensor life · oxygen deficiency and enrichment · H2S exposure limits · CO exposure limit · SO2 exposure limits · NO2 and diesel exhaust · every gas monitor by gas, sampling and battery.
RKI Instruments 04 Series Single-Gas Monitors questions
What is the RKI 04 Series? RKI's pocket-size single gas detectors (2.8 oz, IP-67) that run on two AAA alkaline cells for months at a time: HS-04 (H2S), CO-04 and CO-04C (CO, the C with hydrogen elimination), OX-04 (O2), the CX-04 CO and O2 dual sensor, and the SC-04 for one toxic gas (HCN, NH3, NO2, PH3 or SO2), as RKI lists them.
What gases does the 04 Series detect? Oxygen (O2), hydrogen sulfide (H2S), carbon monoxide (CO), sulfur dioxide (SO2), hydrogen cyanide (HCN), ammonia (NH3), nitrogen dioxide (NO2), phosphine (PH3) across the configurations we stock; the RKI page lists the sensor options H2S, CO, CO (H2-compensated sensor), O2, NH3, Cl2, HCN, NO2, PH3, SO2.
Is the 04 Series intrinsically safe? Yes. RKI states the 04 Series is ATEX/IECEx approved and QPS classified C/US as intrinsically safe, Class I, Division 1, Groups A, B, C, D, as RKI lists them.
How long do the batteries last in the 04 Series? RKI rates continuous operation on two AAA alkaline cells at 9,000 hours (HS-04, CO-04), 6,200 hours (CO-04C), 4,600 hours (CX-04), 3,000 hours (OX-04, SC-04 NH3) and 6,200 hours for the other SC-04 toxic versions.
Does the 04 Series have a pump? No. The 04 Series is a diffusion monitor worn in the breathing zone; RKI lists no pump option for it.