Description
The Draeger CH19701 is the Carbon monoxide 8/a detector tube, measuring range 8 to 150 ppm CO in H2, 10 pump strokes, measuring time approx. 2 min (handbook, p. 148). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Carbon monoxide.
Draeger CH19701 specifications
| Item | Draeger data |
|---|---|
| Part number | CH19701 |
| Gas or substance | Carbon monoxide |
| Tube type | 8/a |
| Measuring range | 8 to 150 ppm CO in H2 |
| Number of strokes (n) | 10 |
| Measuring time | approx. 2 min |
| Standard deviation | ± 10 to 15 % |
| Color change | white → light brown |
| Temperature | 0 to 50 °C |
| Humidity | less than 50 mg H2O/L |
| Reaction principle | 5 CO + I2O5 → I2 + 5 CO2 |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 148, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 148): Acetylene reacts in a similar way to carbon monoxide, but with lower sensitivity. Benzene, halogenated hydrocarbons, and hydrogen sulfide are retained in the pre-layer. At higher concentrations of interfering hydrocarbons and halogenated hydrocarbons, a carbon attachment tube with order no. CH 24 101 should be added upstream. Scissile halogenated hydrocarbons (e.g., trichloroethylene) at high- er concentrations can form chromyl chloride in the pre-layer, which causes yellow-brown discoloration in the indicating layer. A carbon monoxide measurement is not possible with high olefin concentrations.
Note (handbook, p. 148): This Dräger-Tube can only be used to measure carbon monoxide in hydrogen.
Carbon monoxide exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 50 ppm (55 mg/m³) |
| NIOSH REL | TWA 35 ppm (40 mg/m³) C 200 ppm (229 mg/m³) |
| NIOSH IDLH | 1200 ppm |
| CAS number | 630-08-0 |
| Formula | CO |
| Conversion | 1 ppm = 1.15 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Carbon monoxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Carbon monoxide
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| CH29901 | Draeger Carbon Monoxide 0.3%/b Detector Tubes, Box of 10 | 0.3 to 7 Vol% | Box of 10 |
| CH20601 | Draeger Carbon Monoxide 10/b Detector Tubes, Box of 10 | 100 to 3000 ppm / 10 to 300 ppm | Box of 10 |
| 6733051 | Draeger Carbon Monoxide 2/a Detector Tubes, Box of 10 | 2 to 60 ppm / 25 to 300 ppm | Box of 10 |
| 3735950 | Draeger Carbon Monoxide 2/a-P Tubes for Aerotest, Box of 10 | 2 to 60 ppm | Box of 10 |
| 6728511 | Draeger Carbon Monoxide 5/a-P Tubes for Aerotest, Box of 10 | 5-150 ppm | Box of 10 |
| CH25601 | Draeger Carbon Monoxide 5/c Detector Tubes, Box of 10 | 100 to 700 ppm / 5 to 150 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Carbon monoxide detector tubes.
Draeger CH19701 questions
What does the Draeger CH19701 measure? Carbon monoxide in air, measuring range 8 to 150 ppm CO in H2.
How many pump strokes does the CH19701 take? 10 strokes (n) per the handbook, p. 148. Measuring time approx. 2 min.
Which pump does the CH19701 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the CH19701? white → light brown, read against the scale printed on the tube.
Do Draeger CH19701 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of CH19701? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.