Description
The MSA Advantage 3100 Facepiece (Single-Port) is a full facepiece with single-port (chin-type gas mask canister. Our part numbers: 10028998 (Medium, with rubber head harness). Sizes Small, Medium, Large. Ships in 1–2 business days; most orders arrive in 3–7 business days. Advantage 3100: every cartridge, filter, part and NIOSH approval on one page.
MSA Advantage 3100 Facepiece (Single-Port) specifications
| Item | Manufacturer data |
|---|---|
| Facepiece type | Full facepiece |
| Sizes | Small, Medium, Large |
| Our part numbers | 10028998 (Medium, with rubber head harness) |
| Other versions MSA lists | 10028999 (Small, with rubber head harness), 10029000 (Large, with rubber head harness), 10031343 (Small, with European-style harness), 10031342 (Medium, with European-style harness), 10031344 (Large, with European-style harness) |
| Cartridge connection | Single-Port |
| MSA statement | Integrated nosecup helps to reduce lens fogging |
| MSA statement | Scratch-resistant, optically correct wraparound lens enables wide field-of-vision |
| MSA statement | Easy cleaning and decontamination |
Source: MSA Advantage 200 LS and 3200 data sheet 1012-12-MC (05.2020).
MSA canisters we list
| Part number | Canister | Protection | Approval | Facepieces MSA names |
|---|---|---|---|---|
| 10059903 | Phosphine/ammonia/chlorine/P100 canister | Phosphine, Ammonia, Chlorine, P100 | TC-14G-0274 | Chin-type gas mask: G1 (single port APR adapter 10144231-SP required), Advantage 4100 (RD40 adapter 10065330 required), Advantage 3100, Ultravue, Ultra Elite, M |
| 10046570 | CBRN Cap-1 canister, for Millennium, G1 and Ultra Elite Facepieces | CBRN Cap 1 | TC-14G-0270 (Millennium, Ultra Elite demand facepiece); TC-14G-0351 (G1 with single port adapter) (MSA Riot Control Resp | Millennium, Ultra Elite (demand), G1 with single port adapter (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); "The Advantage 4000 ma |
| 817590 | Advantage 1000 Riot Control Agent Canisters, box of 6 | P100 | TC-14G-0235 (Advantage 1000; MSA Riot Control Respiratory Protection for First Responders 1000-102-MC/MSA Advantage 1000 | Advantage 1000 (bayonet canister 817588); Advantage 3200 per MSA Riot Control Respiratory Protection for First Responders 1000-102-MC table (TC-14G-0235) |
| 818264 | Millennium riot control canisters, box of 6 | P100 | TC-14G-0254 (Millennium w/ 818263 or 817589; CEL) | Millennium Gas Mask (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC) |
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021).
Gas mask use is restricted to entry into, or work within, atmospheres that are within canister limitations. They are not intended for oxygen-deficient atmospheres (less than 19.5% O2). Gas masks may be used for escape only from atmospheres in which the contaminant concentration does not exceed the gas mask maximum use concentration. Chin-Type Gas Masks have the following maximum use limitations: Routine use: 50 times the Permissible Exposure Level (PEL) - Do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape use: contaminant concentrations up to gas mask maximum use concentrations, providing there is sufficient oxygen to support life. Gas masks are generally suitable for ventilated areas with relatively stable concentration levels. They should never be used within confined spaces, or where oxygen deficiency and/or high gas concentrations may exist.
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025).
NIOSH approval configurations for the Advantage 3100 Facepiece (Single-Port)
The MSA NIOSH approval insert for this family lists 4 approval configurations:
| Approval | Protection | Cartridge, filter or canister in the configuration |
|---|---|---|
| TC-14G-0274 | P100/PH/AM/CL | 10051287 |
| TC-14G-0279 | P100/OV | 10051287 |
| TC-14G-0280 | P100/HF/CL | 10051287 |
| TC-14G-0282 | P100/FM/AG/CD/HS | 10051287 |
Source: MSA NIOSH approval insert Gas-Mask-Respirator-Family. The insert states the respirator is approved only in the listed configurations.
NIOSH approvals naming the Advantage 3100
The NIOSH Certified Equipment List carries 9 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 4 gas mask / CBRN (TC-14G), 2 powered air-purifying (TC-21C), 1 chemical cartridge (TC-23C), 2 air-purifying particulate (TC-84A).
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-14G-0274 | Advantage 3100 & 4100 / UltraVue / UltraElite /Millennium facepieces, canister p/n 10059903, and accessories | Ammonia, Chlorine, P100, Phosphine | Full Facepiece |
| TC-14G-0279 | UltraVue / UltraElite / Millennium / Advantage 3100 & 4100 Facepieces with 10067469 canister | Organic Vapor, P100 | Full Facepiece |
| TC-14G-0280 | Ultravue / UltraElite / Clearvue / Advantage 3100 & 4100 / Millennium Facepieces with 10067491 canister | Chlorine, Hydrogen Fluoride, P100 | Full Facepiece |
| TC-14G-0282 | Ultravue, Ultra Elite, Clearvue, Advantage 3100 & 4100, Millennium facepieces with 10067470 canister | Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Sulfide, P100, Sulfur Dioxide | Full Facepiece |
| TC-21C-0763 | OptimAir MM2k PAPR w/ Models 4100 and 3100 full facepieces and Type HE filter | HEPA (PAPR only) | Full Facepiece |
| TC-21C-0805 | OptimAir TL PAPR with UltraElite and Advantage 3100 & 4100 Full Facepieces | HEPA (PAPR only) | Full Facepiece |
| TC-23C-4126 | OptimAir TL(7-934-1 &-1C, 7-934-2 &-2C, 7-934-3 &-3C, Ultra Elite )(3100 Adv.)(4100-H Adv. Hycar)(4100-S Adv. Silicone) | High-Efficiency, Mercury Vapor, Organic Vapor | Full Facepiece |
| TC-84A-6718 | Model Advantage 3100 Full Facepiece Belt Mounted Air Purifying Respirator with Filter | P100 | Full Facepiece |
| TC-84A-6719 | Model Advantage 3100 Full Facepiece Belt Mounted Air Purifying Respirator with Filter | P100 | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
| Powered air-purifying full facepiece | 1000 |
| Supplied-air respirator, continuous flow, full facepiece | 1000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Facepiece Material | Silicone |
| Harness | Rubber head harness |
| Color | Blue |
| Body Material | Silicone |
| Resistance | Particles; Gases |
| Includes | Respirator |
| Protected Area | Full Facepiece |
Source: Manufacturer published product data as carried in our catalog.
Advantage 3100 full-facepiece respirator from MSA, size medium, is a NIOSH-approved single-port full face respirator with a silicone facepiece. It uses MSA Advantage single-port canisters and a rubber head harness, a full face canister respirator for contractors who prefer one centered cartridge.
- Full facepiece respirator, size medium
- Silicone facepiece
- Rubber head harness
- Single-port connection for MSA Advantage single-port canisters
- NIOSH approved
Environmental and abatement crews use the 3100 where a single canister keeps weight centered on the face and simplifies canister changes in the field. Manufacturer item number: 10028998. Sold individually.
MSA Advantage 3100 questions
What cartridges fit the MSA Advantage 3100? Single-port (chin-type gas mask canister; OptimAir TL)
What sizes does the Advantage 3100 come in? Small, Medium, Large: 10028998 (Medium, with rubber head harness).
What is the assigned protection factor of a full facepiece? OSHA Table 1 assigns an APF of 50 to an air-purifying full facepiece.
Guides: half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · cartridge change schedules · P100 vs N95 vs R95 · all respirators by model and hazard.
